BATTERY POWERED ELECTRONIC CONVERTER
11
en
BOXEL E-BATT
5
LOCATING MALFUNCTIONS
The device has a green LED on the restart button to inform about alarms.
LED
Description
Action to take
TIME ON
TIME OFF
Off
Off
Normal functioning. Status:
Waiting
None
Normal functioning. Status:
Working
None
15 ms
2 flashes
600 ms
Status: Low battery
Charge the battery
200 ms
200 ms
Output overload
Excess of load connected to the
converter / malfunction of the vibrator
connected to it.
700 ms
50 ms
High temperatura warning
You can keep working until overheating
warning.
Clean the device.
If the warning remains contact the
official service.
15 ms
5 flashes
600 ms
Overheating warning
Clean the device.
If the warning remains contact the
official service.
15ms
6 flashes
600 ms
Battery overvoltage
Send the device to the official service or
a dealer for checking.
15ms
3 flashes
600 ms
Short circuit
Defective poker.
Defective converter.
When a failure warning occurs, press the restart button to reset the alarm.
6
INSTRUCTIONS TO ORDER SPARE PARTS
6.1 INSTRUCTIONS TO ORDER SPARE PARTS
1.-
Every spare parts order must include PART CODE NUMBER AS STATED IN THE PARTS
LIST. We recommend including the MACHINE SERIAL NUMBER.
2.-
The identification plate with serial and model number is located as shown in the point 2 of this
manual.
3.-
Let us to know the right shipping instructions, including the wished route, the address and the
consignee complete name.
4.-
Do not return the parts without authorisation, the return is done with freight prepaid.
Off
Off
Summary of Contents for BOXEL E-BATT