3/5

 

CHIME-100_Rev1.1_022421                          [email protected]

 

 

4.

 

Wire  all  needed  connections  on  the  device.  See  sections  “Outputs”  &  “Inputs”  for  a  detailed 
description of each terminal’s function. The CHIME-100 requires a connection between 

INPUT 1

 

and 

INPUT 2 

to properly function. 

 

Connection 

Description 

VOUT - 

Negative connection from power jack in. Can be used to power other 
low-power devices. (Power adapter included is 9VDC) 

VOUT + 

Positive connection from power jack in. Can be used to power other 
low-power devices. (Power adapter included is 9VDC) 

INPUT 1 

Closing the connection between these inputs will trigger the melody. 
It can be connected to a relay, switch, pushbutton, transistor, etc.… 

INPUT 2 

NPN OUT 

An open collector transistor output which will pull down to ground 
when activated. This output can handle 170mA at 100VDC 

RE

LA

O

U

NC  Normally-closed output connection 

COM  Common output connection 

NO  Normally-open output connection 

 

 

5.

 

All wiring should pass through the cable grip. Tighten down the cable grip once wiring is complete. 

6.

 

Check that the inputs are being properly recognized. The red

 Presence LED

 (see below) will turn 

on when the input is activated. If the input shorting lasts longer than 30 seconds, the presence 
LED will begin blinking. 

 

 

 

7.

 

Configure the CHIME-100 to play the desired melody by pressing the pushbutton on the side of 
the unit. Adjust the volume to a comfortable level. See section 

“Chime Adjustment”

 on next page 

for more information. 

8.

 

Reattach the lid to the base and screw down firmly. Test the setup again to ensure the correct 
chime plays at a comfortable listening level. 

 
 

 