CS202S-5W-50 

CarSense 202 5-wire, 50ft. lead-in wire 

 

CS202S-5W-100 

CarSense 202 5-wire, 100ft. lead-in wire 

 

CS202S-5W-XX 

CarSense 202 5-wire, (enter required length in ft.) lead-in wire 

 

Wiring Connections 

 

 
 

 
 
 
 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

Accessories for CS202 

Wire Color 

Description 

Red 

Power + (9 to 41VDC or 6 to 29VAC) 

Black 

Power 

 (9 to 41VDC or 6 to 29VAC) 

Green 

Common (relay common contact) 

White 

N.C. (relay normally closed contact) 

Brown 

N.O. (relay normally open contact) 

Red 

Power + (6 to 29VAC) 

Black 

Power 

 (6 to 29VAC) 

White 

N.C. (relay normally closed contact) 

Brown  N.O. (relay normally open contact) 
Green 

Common (relay common contact) and 
earth ground 

White 

N.C. (relay normally closed contact) 

Brown  N.O. (relay normally open contact) 
Green 

Common (relay common contact) 

Red 

Power + (9 to 41VDC) 

Black 

Power 

 (9 to 41VDC) and earth ground 

 

IMPORTANT:  EARTH GROUND CONNECTION 

 

The CS202 contains transient protection devices to guard the sensitive electronic circuitry from 
damage and false triggering due to electrical transients caused by lightning or other sources. Always 
provide a good earth ground.  An 8ft. copper rod or metal cold-water pipe provides a sufficient earth 
ground connection. 

 

When using 

AC power

, connect the CS202 green common relay and earth ground wire to the 

operator. 

 

When using 

DC power

, connect the CS202 black power (

) wire and the opera

tor’s ground, common 

or power (

) lead to the earth ground. 

 

 