EMX Industries, Inc.
Tech support: 216-834-0761
2/5
CS202_Rev1.6_070119 [email protected]
•
CS202S-5W-50
CarSense 202 5-wire, 50ft. lead-in wire
•
CS202S-5W-100
CarSense 202 5-wire, 100ft. lead-in wire
•
CS202S-5W-XX
CarSense 202 5-wire, (enter required length in ft.) lead-in wire
Wiring Connections
Accessories for CS202
Wire Color
Description
Red
Power + (9 to 41VDC or 6 to 29VAC)
Black
Power
–
(9 to 41VDC or 6 to 29VAC)
Green
Common (relay common contact)
White
N.C. (relay normally closed contact)
Brown
N.O. (relay normally open contact)
Red
Power + (6 to 29VAC)
Black
Power
–
(6 to 29VAC)
White
N.C. (relay normally closed contact)
Brown N.O. (relay normally open contact)
Green
Common (relay common contact) and
earth ground
White
N.C. (relay normally closed contact)
Brown N.O. (relay normally open contact)
Green
Common (relay common contact)
Red
Power + (9 to 41VDC)
Black
Power
–
(9 to 41VDC) and earth ground
IMPORTANT: EARTH GROUND CONNECTION
The CS202 contains transient protection devices to guard the sensitive electronic circuitry from
damage and false triggering due to electrical transients caused by lightning or other sources. Always
provide a good earth ground. An 8ft. copper rod or metal cold-water pipe provides a sufficient earth
ground connection.
When using
AC power
, connect the CS202 green common relay and earth ground wire to the
operator.
When using
DC power
, connect the CS202 black power (
–
) wire and the opera
tor’s ground, common
or power (
–
) lead to the earth ground.
AC Wiring Diagram
DC Wiring Diagram