ULT-

PLG™ Operating Instructions 

 

Document no.

  10180904 

 

 

 

Controls and Indicators 

 

AUTOMATIC SENSITIVITY BOOST 

 
 
 

PRESENCE

 

 
 
 
 

 

DETECT-ON-STOP (DOS)  

 

 
 
 

        OUTPUT B

 

 
 
 
 

 
 

 

(1)

 

Not used when DOS is selected 

 

        FAIL SAFE / SECURE

 

 
 
 

 

FREQUENCY SETTINGS 

 
 
 
 

 
 

 

SENSITIVITY SETTING 

 

 
 

DETECT / FREQUENCY COUNT 

 

 

 
 
 

 

ULTRAMETER™ DISPLAY 

 

Indicates sensitivity setting required to detect vehicle 

 
        

 

FREQUENCY COUNT / RESET 

 Press to start frequency count, re-initializes after count 

 

 

 

 

DIP switch position 8 

ASB enabled 

on 

 

DIP switch position 7 

NORMAL (5 min.) 

on 

INFINITE 

off 

 

DIP switch position 6 

DOS on 

on 

DOS off 

off 

 

DIP switch position 

MODE 

Pulse on Entry 

on 

on 

Pulse on Exit(1) 

off 

on 

B same as A 

on 

off 

Loop Fault 

off 

off 

 

DIP switch position 3 

Fail Secure 

on 

Fail Safe   

off 

 

DIP switch position 

FREQUENCY 

Low 

on 

on 

Medium low 

on 

off 

Medium high 

off 

on 

High 

off 

off 

 

Position 0…….9 

Sensitivity 

Low……….high 

     

Red LED 

Presence detected 

on 

No presence 

off 

Frequency count 

flashing 

Summary of Contents for ULT-PLG ULTRALOOP

Page 1: ...O N S Operating Instructions 4564 Johnston Parkway Cleveland Ohio 44128 P 800 426 9912 F 216 518 9884 Sales Inquiries salessupport emxinc com Technical Support technical emxinc com www emxinc com ULT...

Page 2: ...Instructions 1 Document no 10180904 Contents Cautions and Warnings 2 Product Overview 2 Specifications 3 Operation 4 Controls and Indicators 6 Connections 7 Troubleshooting 8 Loop Installation 9 Order...

Page 3: ...PLG may be used in Center Safety and Exit loop positions The UltraMETER display feature makes set up easy by displaying the optimum sensitivity setting required to detect a vehicle positioned on the...

Page 4: ...ntal tracking Automatic compensation Surge protection Loop circuitry protected by surge suppressors Detect output Solid state Output B Solid state Output B inverted Solid state Power loop fault indica...

Page 5: ...o detect a vehicle on the loop To use this feature observe the display while a vehicle is moving into position on the loop note the number displayed then adjust the sensitivity setting rotary switch t...

Page 6: ...or Infinite Presence or Normal Presence Infinite Presence causes the output to remain in detect mode as long as the vehicle remains on the loop Normal Presence causes the output to reset after 5 minut...

Page 7: ...Press to start frequency count re initializes after count DIP switch position 8 ASB enabled on DIP switch position 7 NORMAL 5 min on INFINITE off DIP switch position 6 DOS on on DOS off off DIP switc...

Page 8: ...Instructions 7 Document no 10180904 Connections Connector pin Description 1 Loop 2 Loop 3 Power 12VDC 24VDC 4 No connection 5 No connection 6 Output B 7 Output B inverted 8 Presence output 9 Power 12V...

Page 9: ...d sealed against moisture 4 Observe ULTRAMETER display level indicated on display indicates residual frequency shift from vacant loop to vehicle presence press Frequency Count switch to re initialize...

Page 10: ...saw cut Place backer material into the saw cut over the loop wire and pack tightly Place a high quality sealer over the saw cut to seal the surface RESURFACE ASPHALT Saw cut the existing surface deep...

Page 11: ...d products damage caused by incorrect connections lightning damage or use other than intended design There is no warranty of merchantability There are no warranties expressed or implied or any affirma...

Page 12: ...ULT PLG Operating Instructions 11 Document no 10180904 BLANK PAGE...

Page 13: ...ULT PLG Operating Instructions 12 Document no 10180904 BLANK PAGE...

Page 14: ...cument no 10180904 4564 Johnston Parkway Cleveland Ohio 44128 United States of America www emxinc com Technical Support 216 834 0761 technical emxinc com Sales 216 518 9888 Fax 216 518 9884 salessuppo...

Reviews: