PLG™ Operating Instructions
6
Document no.
10180904
Controls and Indicators
AUTOMATIC SENSITIVITY BOOST
PRESENCE
DETECT-ON-STOP (DOS)
OUTPUT B
(1)
Not used when DOS is selected
FAIL SAFE / SECURE
FREQUENCY SETTINGS
SENSITIVITY SETTING
DETECT / FREQUENCY COUNT
ULTRAMETER™ DISPLAY
Indicates sensitivity setting required to detect vehicle
FREQUENCY COUNT / RESET
Press to start frequency count, re-initializes after count
DIP switch position 8
ASB enabled
on
DIP switch position 7
NORMAL (5 min.)
on
INFINITE
off
DIP switch position 6
DOS on
on
DOS off
off
DIP switch position
MODE
4
5
Pulse on Entry
on
on
Pulse on Exit(1)
off
on
B same as A
on
off
Loop Fault
off
off
DIP switch position 3
Fail Secure
on
Fail Safe
off
DIP switch position
FREQUENCY
2
1
Low
on
on
Medium low
on
off
Medium high
off
on
High
off
off
Position 0…….9
Sensitivity
Low……….high
Red LED
Presence detected
on
No presence
off
Frequency count
flashing