4
SSSSS
: 00000 ~ 00999
EEEEE
: 00000 ~ 00999
If
SSSSS
>
EEEEE
or
SSSSS
>00999 or
EEEEE
>00999, error message.
10*SSSSS9EEEEE#
Delete the proximity cards with addresses starting from
SSSSS
to
EEEEE
from
system.
SSSSS
: 00000 ~ 00999
EEEEE
: 00000 ~ 00999
If
SSSSS
>
EEEEE
or
SSSSS
>00999 or
EEEEE
>00999, error message.
11*SSSSS*EEEEE#
Enable the proximity cards with addresses starting from
SSSSS
to
EEEEE
. After
enabled, the cardholder(s) can access the system by using "
Card Only
" mode.
SSSSS
: 00000 ~ 00999
EEEEE
: 00000 ~ 00999
If
SSSSS
>
EEEEE
or
SSSSS
>00999 or
EEEEE
>00999, error message.
12*SSSSS*PPPP#
Enable a proximity card with addresses
SSSSS
and assign a
PIN Code
PPPP
to it. After assigned, the cardholder can access the system by using "
Card or
PIN Code
" mode. For example:
After entering
12*00005*7766#
, user can access the door by just either
‘presenting the card with address #00005 to the reader’ or “entering the address
no.
00005
and then
7766#
.
SSSSS
: 00000 ~ 00999
PPPP
: 0001 ~ 9999
If
SSSSS
>00999, error message.
13*SSSSS*PPPP#
Enable a proximity card with addresses
SSSSS
and assign a
PIN Code
PPPP
to it. After assigned, the cardholder can access the system by using "
Card and
PIN Code
" mode. For example:
After entering
13*00005*7766#
, user can access the door by just presenting
the card with address #00005 to the reader and then entering
7766#
.
SSSSS
: 00000 ~ 00999
PPPP
: 0001 ~ 9999
If
SSSSS
>00999, error message.
17*FFFF#
Assign 4-digit
Function Code
FFFF
.
Function Code
followed with
<#>
to
Arm
or
Disarm
the system.
Function Code
followed with
<DEV>
to activate the
Alarm Relay
.
FFFF
: 0001 ~ 9999
Default setting:
FFFF
= 1234
18*TTT#
Arming Idle Time
Setting. 1 ~ 600 seconds.
TTT
= 001 ~ 600.
If
TTT
>600, system will assign a default setting.
Default setting:
TTT
= 015
19*SSSSS*NNNNN#
Register a number of card(s) to the system. After registered, the cardholder can
access the system by using "
Card Only
" mode.
Note: Cards can not be
registered through 721K or 721U
.
SSSSS
: 00000 ~ 00999. Register Card(s) with addresses starting from
SSSSS
.
NNNNN
: Indicate a number of card(s) to be registered.
If
NNNNN=
00001 Single card registration.
Card Codes
can be either in sequential or in random, after
#
sign, user can
register the proximity cards to the system by present the cards to the reader
panel one by one continuously. For each valid card registration, the system will
automatically assign a group number to each card and increment the address by
one. Before each registration, system will also perform the following checking:
A
card registered can not be registered again, five beep tones are generated
to indicate this error
.
If
NNNNN=
00002 – 00999 Block registration.
If
Card Codes
are in sequential with same
Site Code
, after
#
sign, user can
register the proximity cards to the system by just present the card with the
lowest
Card Code
to the reader panel. The system will automatically assign a
group number and the addresses starting from
SSSSS
to the proximity cards.
System will refuse the block registration if card(s) is (are) registered
before, five beep tones are generated to indicate this error
.
Cards have
already been registered in these block addresses will be overwritten.
Cards with same
Site Code
are automatically assigned to same group number