Softsynchro
®
6
14
Operating instruction edition: 01.04.2018
3 Maintenance
3.1 Maintenance schedule
What?
When?
Who?
External cleaning
Periodically, depending on the degree
of dirt
Operator
3.2 External cleaning
Clean the quick-change tap holder at periodic intervals with a duster, depending on
how dirty the holder is.
Attention
Do not use any aggressive solvents.
Do not use fibrous materials i.e. steel wool.
Do not clean and dry the quick-change tap holder in an automatic washplace, as a
result the built-in dampers and seals may be damaged.
4 Storage when not in use
If the collet holder is taken out of service, please go through the following steps:
-
Clean the quick-change tap holder with a duster, see chapter 3.2
-
Spray the quick-change tap holder with preservation oil to avoid rusting
Attention
Before storage, all evidence of coolant and machining residues must be removed!