3-3
Front Panel Operation
DataNex
EMS Wireless,
DATA-20
Digital Radio
3.2.3
LED Status Indicators
Table 3-1. LED Status Indicator Functions
LED Name
Function
RX
Receiver
Green indicates that the receiver is enabled, the
synthesizer is phase-locked, and a signal is
being received.
RXD
Receive Data
Green indicates that valid data is being received.
BER
Bit Error Rate
Flashes red for each data error detected.
FLT
Fault
General fault light (red). Consult the STATUS
menus for out of tolerance conditions.
LBK
Loopback
Red indicates analog or digital loopback is
enabled.
TXD
Transmit Data
Green indicates the modem clock is phase-
locked and data is being sent.
TX
Transmitter
Green indicates the transmitter is radiating, and
the RF output (forward power) is above the
factory-set threshold.
3.2.4
Screen Menu Tree Structure
Figures 3-2a, b and c, located on pages 3-7, 3-8, 3-9 and 3-10, show the tree structure of the
screen menu system. The figures group the screens into functional sets. There may be minor
differences in the purchased unit, due to software enhancements and revisions. The current
software revision may be noted in the
SYSTEM
sub-menu (under
INFO
).
In general, <
ENTER
> will take you to the next screen from a menu choice, <
UP
> or <
DOWN
> will
scroll through screens within a menu choice, and <
ESC
> will take you back up one menu level.
Certain configuration screens have exceptions to this rule, and are noted later in this section.
CAUTION
DO NOT change any settings in the CONFIGURE or CALIBRATE screens. The
security lock-out features of the software may not be fully implemented, and
changing a setting will most likely render the system non-operational!
Summary of Contents for DataNex Data-20
Page 7: ......
Page 65: ......
Page 72: ...5 5 Appendix DataNex EMS Wireless DATA 20 Digital Radio ...
Page 73: ...Appendix 5 6 DataNex EMS Wireless DATA 20 Digital Radio ...