8
DirectShow
If you change the link ordering after installation you must run dplinks.exe. This program will update the
existing input names used by the Windows® DirectShow interface.
To run the dplinks program open the
Run
by clicking on
Start/Run
and type dplinks and then press Enter.
The program will run, however no notifications are displayed.
Firmware Upgrades
The Xtreme-HD4 cards allow
firmware
upgrade to be completed on site rather than returning the card to
EMS. Whenever a
firmware
upgrade is performed, the J1 Link
MUST BE FITTED on the
Xtreme-HD4. To
perform the upgrade, follow the step-by-step instructions provided by the upgrade application.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power outage) it
is possible to revert to the factory settings by powering down the system, temporarily removing the J1 link
then powering up the system with the link removed. Once the system has rebooted, replace the J1 link
link (whilst the system is powered up) and restart the
firmware
upgrade process.
It should be noted that the latest driver installation program includes an automatic
firmware
update, if
required. Therefore, prior to installing the application and driver, ensure that J1 link is
fitted.
Software Installation
Software Installation
The Xtreme software (driver and application) is installed from www.ems-imaging.com/downloads
The installation process should start automatically.
Follow the installation wizard instructions as prompted.
Regular software updates are available from our website: