Emplus WAP380 User Manual Download Page 47

46 

 

In Italy the end-user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links 
and/or for supplying public access to telecommunications and/or network services. 
This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range 
of 2454 

 2483.5 MHz. For detailed information the end-user should contact the national spectrum authority in France. 

 
The frequency and the maximum transmitted power in EU are listed below: 
2402-2480MHz: 4.35dBm  
2412-2472MHz: 15.35dBm  
5150-5250 & 5725-5850MHz: 18.15dBm 
 

 

Česky [Czech]

 

[Jméno výrobce]

 

tímto prohlašuje, že tento 

[typ zařízení]

 

je ve shodě se základními požadavky a 

dalšími příslušnými ustanoveními směrnice 1999/5/ES.

 

Dansk [Danish] 

Undertegnede 

[fabrikantens navn]

 erklæ rer herved, at følgende udstyr 

[udstyrets typebetegnelse]

 

overholder de væ sentlige krav og øvrige relevante krav i direktiv 1999/5/EF. 

Deutsch [German] 

Hiermit erklärt 

[Name des Herstellers]

, dass sich das Gerät 

[Gerätetyp]

 in Ü bereinstimmung mit den 

grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 
1999/5/EG befindet. 

Eesti [Estonian] 

Käesolevaga kinnitab 

[tootja nimi = name of manufacturer]

 seadme 

[seadme tüüp = type of 

equipment]

 vastavust direktiivi 1999/5/EÜ  põhinõuetele ja nimetatud direktiivist tulenevatele teistele 

asjakohastele sätetele. 

English 

Hereby, 

[name of manufacturer]

, declares that this 

[type of equipment]

 is in compliance with the 

essential requirements and other relevant provisions of Directive 1999/5/EC. 

Español [Spanish] 

Por medio de la presente 

[nombre del fabricante]

 declara que el 

[clase de equipo]

 cumple con los 

requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 
1999/5/CE. 

Ελληνική [Greek]

 

ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ

 [name of manufacturer] 

ΔΗΛΩΝΕΙ ΟΤΙ

 [type of equipment] 

ΣΥΜΜΟΡΦΩΝΕΤΑΙ 

ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.

 

Français [French] 

Par la présente 

[nom du fabricant]

 déclare que l'appareil 

[type d'appareil]

 est conforme aux 

exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. 

Italiano [Italian] 

Con la presente 

[nome del costruttore]

 dichiara che questo 

[tipo di apparecchio]

 è conforme ai 

requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. 

Latviski [Latvian] 

Ar šo 

[name of manufacturer  / izgatavotāja nosaukums] 

deklarē, ka 

[type o 

f equipment / iekārtas tips]

 

atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to 

Summary of Contents for WAP380

Page 1: ...0 User Manual WAP380 Version 1 0...

Page 2: ...1 IMPORTANT To install this Access Point Please refer to the Quick Installation Guide included in the product packaging...

Page 3: ...2 Chapter1 Product Overview...

Page 4: ...ction for beacon scanning The AP is 802 11 ax ac a b g n Indoor Access Point with speeds up to 1200 Mbps on 2 4GHz and 2400 Mbps on 5GHz band It can be configured as an Access Point or WDS AP Station...

Page 5: ...4 Physical Interface WAP380...

Page 6: ...tennas Interface 1 x 10 100 1000 2500Mbps Ethernet Port with 802 3af at PoE 1 x 10 100 1000Mbps Ethernet Port 1 x DC power connector 1 x USB 2 0 port 1 x reset button Dimensions W x D x H 205x205x34 m...

Page 7: ...6 Mounting...

Page 8: ...7...

Page 9: ...Mount an Access Point 6 Slide the pole mount base into the slot of the Access Point 7 Attaching the Straps to the Pole Mount Bracket 8 Lock and tighten the strap to secure the pole mount bracket to th...

Page 10: ...where one wants either a permanent or temporary Wireless LAN established The Ability to Access Real Time Information Doctors Nurses Point of Sale Employees and or Warehouse Workers can access real ti...

Page 11: ...10 Chapter2 Before You Begin...

Page 12: ...rWindowsOScomputersystem 1a Click the Start button and open the Control Panel WindowsXP Windows7 1b Move your mouse to the lower right hot corner to display the Charms Bar and select the Control Panel...

Page 13: ...Network and Internetsection then select Change adapter settings 3 Right click on Local Area Connection and select Properties 4 Select Internet Protocol Version4 TCP IPv4 and then select Properties 5 S...

Page 14: ...13 Note EnsurethattheIPaddressandSubnetmaskare on the same subnet as the device For example WAP380 IP address 192 168 1 1 PC IP address 192 168 1 2 192 168 1 255 PC Subnet mask 255 255 255 0...

Page 15: ...tion 3 HighlightEthernet 4 In Configure IPv4 select Manually 5 Enter an IP address that is different from the AccessPoint and Subnet mask then press OK Note Ensure that the IP address and Subnet mask...

Page 16: ...15 Chapter 3 Configuring Your Access Point...

Page 17: ...web browser Internet Explorer Firefox Safari Chrome and enter the IP Address http 192 168 1 1 Note If you have changed the default LAN IP Address of The Access Point ensure you enter the correct IP A...

Page 18: ...17 Chapter4 Building a Wireless Network...

Page 19: ...Point Mode AP be have slikes a central connection for stations or clients that support IEEE802 11ac a b g n networks The stations and clients must be configured to use the same SSID Service Set Identi...

Page 20: ...19 Chapter5 Status...

Page 21: ...evice Status link under the Overview menu shows the status information about the current operating mode The Device Information section shows general system information such as Device Name MAC Address...

Page 22: ...lient and status of Spanning Tree protocol STP The Wireless LAN Information 2 4 GHz 5 GHz section shows wireless information such as Operation Mode Frequency and Channel Since this Access Point suppor...

Page 23: ...and WDS AP modes 2 4 GHz 5 GHz WDS Link List Click the connection link under the Overview menu This page displays the current status of the WDS link including WDS Link ID MAC Address Link Status and R...

Page 24: ...23 Chapter6 Network...

Page 25: ...n the IP address field or be obtained automatically when the device connects to a DHCP server IP Address The IP address of this device Subnet Mask TheIP Subnet mask ofthis device Gateway The Default G...

Page 26: ...25 Chapter7 2 4GHz 5GHz Wireless...

Page 27: ...dual band capable client Devices to network to the 2 4GHz band only if the client devices are not currently associated on 2 4GHz radioin this AP Prefer 5GHz When band steering is configured to Prefer...

Page 28: ...lementing on this radio The default operation mode is Access Point on base stations and Access Points and is Client Bridge on Client Premise Equipements CPE Meanwhile EnGenius outdoor devices also sup...

Page 29: ...dio Considering the different applications users can decide to implement a channel bandwidth to fulfill real applications The larger the channel the greater the transmission quality and speed Transmit...

Page 30: ...owered RTS CTS Threshold Specifies the threshold package size for RTC CTS A small number causes RTS CTS packets to be sent more often and consumes more bandwidth Client Limits Limits the total number...

Page 31: ...can configure up to sixteen 16 different SSIDs eight 8 per band If multiple client devices will be accessing the network you can arrange the devices into SSID groups Click Edit to configure the profil...

Page 32: ...utton to enable this function for allowing or preventing communication between client devices VID Specifies the VLAN tag for each profile If your network includes VLANs you can specify a VLANID for pa...

Page 33: ...Hexadecimal Numbers For advanced users Key Length Select the desired option and ensure that wireless clients use the same setting Your choices are 64 128 and 152 bit password lengths Default Key Selec...

Page 34: ...must be from 8 to 63 characters in length If using HEX format the Key must be 64HEX characters in length Group Key Update Interval Specifies how often in seconds the Group Key changes The default val...

Page 35: ...ver RadiusAccountingPortEntertheportnumberusedfor connectionstotheRadiusaccountingserver RadiusAccountingSecret Enterthesecretrequiredto connect to the Radius accounting server InterimAccountingInterv...

Page 36: ...ltsettingis DisableWireless MACFilter Note OnlyapplicableinAccessPointandWDSAP modes ACLMode Determineswhethernetworkaccessisgranted ordeniedtoclientswhoseMACaddressesappearinthe MACaddresstableonthis...

Page 37: ...ility Alsonote AllAccessPointsintheWDSnetworkneed tousethesameChannelandSecuritysettings TocreateaWDSnetwork pleaseentertheMACaddresses oftheAccessPointsthatyouwantincludedintheWDS Therecanbeamaximumo...

Page 38: ...inginto the New Password entry box Verify Password Re enter the new password in the ConfirmPasswordentryboxforconfirmation Apply Click Apply to apply the changes Firmware Upgrade Thispageallowsyoutoup...

Page 39: ...ifyouhaveset theAPincorrectly youcanusetheResetbuttoninthe ReverttoFactoryDefaultSettingssectiontorestore alltheconfigurationsoftheAPtotheoriginaldefault settings Backup Setting Click Export to save t...

Page 40: ...ackup theusersettingsyouwouldliketothedevice smemory forthedefaultsettings RestoretoUserDefault ClickRestoretorestoreuser settings to the factory standard settings Note1 Aftersettingthecurrentsettings...

Page 41: ...rds eventsofpossible interestinitsinternalmemory Toviewthelogged information clicktheLoglinkundertheSystemManager menu Ifthereisnotenoughinternalmemorytologall events oldereventsaredeletedfromthelog W...

Page 42: ...oot ClickonReset toreboottheAP Onceyouclickresetbutton youwillseetheoptionsforreboot or restore this AP Rebootthedevice Clickittorebootthisdevice RestoretoFactoryDefault Clickittoresetthisdevicetofact...

Page 43: ...ct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a cir...

Page 44: ...ind sirable Caution i the device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite systems ii high power r...

Page 45: ...uipement est conforme aux limites d exposition aux rayonnements IC tablies pour un environnement non contr l Cet quipement doit tre install et utilis avec un minimum de 21cm de distance entre la sourc...

Page 46: ...TE Directive EN 301 893 Broadband Radio Access Networks BRAN 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3 2 of the R TTE Directive EN 301 489 1 Electromagneti...

Page 47: ...nden Anforderungen und den brigen einschl gigen Bestimmungen der Richtlinie 1999 5 EG befindet Eesti Estonian K esolevaga kinnitab tootja nimi name of manufacturer seadme seadme t p type of equipment...

Page 48: ...asadniczymi wymogami oraz pozosta ymi stosownymi postanowieniami Dyrektywy 1999 5 EC Portugu s Portuguese Nome do fabricante declara que este tipo de equipamento est conforme com os requisitos essenci...