26532-14-0914
Page 16
BEFORE FULLY INSTALLING THE APPLIANCE
Set Up Procedure: (Figures 12a and 12b)
1. Remove top cover assembly as illustrated by Figure
15. Remove three #8 x 1/2" Phillips Head screws from
the front edge, then gently lift upward on the top cover
assembly to pivot. Shift the top cover to the right and
rearward to disengage the locking tabs at rear flange.
2. Set top cover assembly to the side until all gas connec-
tions, wiring, base securement and leakage tests are
conducted.
3. Center the gas appliance base in the fireplace or firebox.
Make certain the front edge of the burner sits inside the
front edge of the fireplace or firebox opening.
4. Anchor holes are provided in the bottom base (or optional
support legs) of the burner housing. After centering the
burner base correctly, mark the hole positions on the
fireplace/firebox floor. Drill two 5/32" diameter holes ap
-
proximately 1-1/2" deep for masonry screws or 1/8" hole
for sheet metal screws.
5. Anchor the base assembly to the fireplace/firebox floor
using the screws provided. Refer to Figure 12a or 12b.
6. Reinstall top cover to base with three #8 x 1/2" screws.
Proper installation of the base is essential to prevent
any movement of the burner and controls during opera-
tion.
ANCHOR SCREW
LOCATIONS
VFRL Series without support legs installed
Figure 12a
ANCHOR SCREW
LOCATIONS
VFIL Series with support legs installed
Figure 12b