Empire OLL60FP12SN-1 Installation Instructions And Owner'S Manual Download Page 30

35008-1-0515

Page 30

OLL60Fp pARTS LIST

USE ONLY MANUFACTURER'S REpLACEMENT pARTS. USE OF ANY OTHER pARTS COULD CAUSE INJURY OR DEATH.

INDEX 

NO.

pART 

NO.

DESCRIpTION

QTY REQ
NAT Lp

1

35831

NON-COMBUSTIBLE 

BOARD, TOP

1

1

2

R11981 GLASS

1

1

3

35007

CONTROL DOOR

1

1

4

34182

NAILING FLANGE

4

4

5

33641

NON-COMBUSTIBLE 

BOARD, SIDE

2

2

6

35595

BURNER PLATE ASSEMBLY

1

1

7

R11986 LIGHT STRIP LED

2

2

8

R11919 CONTROL MODULE LED

1

1

9

R11920 TRANSFORMER LED

1

1

10

R11921 SWITCH BUTTON

2

2

11

R11924 WIRE HARNESS SWITCHES

1

1

12

B072218 IGNITOR ELECTRONIC

1

1

13

R11932 GROUNDWIRE

1

1

14

R11923 IGNITOR ASSEMBLY

1

1

15

33256

THERMOCOUPLE BRACKET

1

1

16

B101961 CLIP - ELECTRODE

1

1

17

R685

THERMOCOUPLE 22 IN

1

1

18

35600

BURNER WELDED 

ASSEMBLY

1

1

19

33258

TUBING ASSEMBLY SUPPLY

1

1

20

P271

FITTING ORIFICE

1

1

21

R10808 AIR SHUTTER STAINLESS

1

1

22

P279

ORIFICE #14

1

0

22

P256

ORIFICE #41

0

1

23

B101848 GAS CONTROL KNOB

1

1

24

R7195

CONNECTOR BRASS MALE

1

1

25

R11916 VALVE LP MANUAL

0

1

25

R11829 VALVE NAT MANUAL

1

0

26

R8898

NIPPLE 3/8 X 3/8 X 1 BLACK 

IRON

1

0

27

R7160

REGULATOR 4.5 W.C. (NAT)

1

0

28

R12078 FITTING BRASS 

1/2 FLARE X 3/8 MIP

1

1

29

R12077 FLEX LINE

1

1

30

R1652

NUT LOCK (VALVE)

1

1

31

R11982 COVER SCREEN LIGHTS

1

1

32

35604

COVER SCREEN LIGHTS 

WITH CUT-OUT

1

1

33

R11843 CONTROL DOOR SCREW

3

3

34

35832

GASKET

2

2

35

33957

GASKET

2

2

36

R11891 VENTURI BUG SCREEN

1

1

37

R11942 JUNCTION BOX

1

1

38

R3492

RECEPTACLE

1

1

39

R11943 JUNCTION BOX COVER

1

1

N/S

34330

BURNER SERVICE 

SUPPORT

2

2

N/S

R11944 CONDUIT CONNECTOR

1

1

N/S

R11387 CONTROL PANEL SCREWS

2

2

N/S

34179

HARDWARE PACK

1

1

N/S

R11955 LED MODULE WEATHER 

PLUG (INCLUDED WITH #8)

3

3

N/S - NOT SHOWN

INDEX 

NO.

pART 

NO.

DESCRIpTION

QTY REQ
NAT Lp

Summary of Contents for OLL60FP12SN-1

Page 1: ...DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper te...

Page 2: ...nance See page 27 Tools Needed 1 1 8 inch Allen Wrench 2 Adjustalbe wrenches with range of 1 inch for gas connection 2 Adjustable pipe wrenches 1 Phillips Screwdriver CARTON CONTENTS INDEX NO DESCRIPT...

Page 3: ...PLACE INSTALLATION FRAMING INSTALLATION 14 15 ELECTRICAL SUPPLY 16 GAS SUPPLY 17 LP GAS CYLINDER INFORMATION 18 19 FINISHING 20 22 LIGHTING INSTRUCTIONS 23 MAIN BURNER FLAME CHARACTERISTICS 24 OPERATI...

Page 4: ...Please leave these instructions with the owner for future reference This unit complies with ANSI Z21 97 CSA 2 41 for Outdoor Gas Fireplaces InstallationandrepairshouldbedonebyaQUALIFIEDSERVICE PERSON...

Page 5: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Page 6: ...Topaz Clear DG1AB 1 2 in Decorative Glass Droplets Aqua Blue DG1GC 1 2 in Decorative Glass Droplets Glacier Ice DG1SL 1 2 in Decorative Glass Droplets Sangria Luster Note Decorative Glass Droplets ma...

Page 7: ...e changing spud orifice size Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail registration card supplied...

Page 8: ...19 3 16 21 5 8 24 10 Figure 2 Mantel Clearances Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 1 COMBUSTIBLE MATERIALS No greeting cards stockings or o...

Page 9: ...replace opening 16 in of non combustible material is provided to allow for placement of wall joint in a cooler temperature zone NON COMBUSTIBLE WALL BOARD PROVIDED Framing Header Fireplace Opening 2 1...

Page 10: ...The width of the firebox opening 60 60 F The interior depth of the firebox not shown 19 23 7 8 G The rear exterior width of the firebox not shown 60 60 K Height from the bottom of the box to the gas l...

Page 11: ...NOTICE This fireplace is NOT equipped with an Oxygen Depletion Sensor ODS pilot Installation of the fireplace may be in an open area however it is recommended that this fireplace be installed in an a...

Page 12: ...equires that a flexible fireplace connector cannot exceed three feet in length A flex line connection to the valves is provided The gas shut off valve must be located outside of the unit in an accessi...

Page 13: ...with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 Latest Edition A factory installed junction box is located on the lower right side of the fireplace The...

Page 14: ...eplace Framing Before completing the framing and installing fireplace provide a path for water drainage out of the fireplace Determine if the optional accessory drain pan will be used See Page 12 If t...

Page 15: ...f the control panel with a Phillips head screw driver See Figure 15 Figure 15 d Lift front of burner assembly and tilt upwards and toward the back of the fireplace Retrieve the two supports from insid...

Page 16: ...use A connector for the junction box to accommodate 1 2 in conduit is supplied in the instruction envelope The fireplace receptacle must be connected to an external GFI protected outlet installed nea...

Page 17: ...ct your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be ch...

Page 18: ...en achieved It is also equipped with an excess flow device In order to attain full flow to the fireplace the valve must be in the off position when the cylinder valve is turned on WARNING A fire will...

Page 19: ...r surface of the floor of the LP gas supply cylinder enclosure and the ground Cylinder valves shall be readily accessible for hand opera tion A door on the enclosure to gain access to the cylinder val...

Page 20: ...d in step 7 on page 15 and reinstall the control door and center pivot pin 4 Unscrew the ignitor button and install the AA battery provided in the instruction envelope prior to closing the control doo...

Page 21: ...with screws into the frame and pre drill and counter sink 1 8 in diameter holes into the fireplace face Finish remain ing wall with weather proof wallboard Note Areas where the steel has been formed c...

Page 22: ...een and burner enough media to cover approximately 10 square feet Ensure coverage is even and not thicker in places Some pieces of broken glass may be larger than others It is fine to use these pieces...

Page 23: ...cover s must be removed before use Remove any debris including leaves and insects from the burner area and the bed of crushed glass 1 Before turning on the main gas supply press the ignitor button Ver...

Page 24: ...urs with the burner at the highest setting Any odors remaining after this initial break in will disappear with continued use Flames from the main burner should be visually out before the weather door...

Page 25: ...hen not in use LED Mode Button Press the Mode Button to adjust LED light system from Automatic Color Changes to Individual Colors 1 Auto cycle Rapid 2 Auto cycle Gradual 3 Pause Auto cycle 4 Deep Blue...

Page 26: ...oper and dangerous operation Verify proper operation after servicing WIRING YELLOW RED BLACK BLACK BLACK RED BLACK LED STRIP LED STRIP TRANSFORMER CONTROL MODULE BLACK BLACK BLACK R11931 LEFT BUTTON B...

Page 27: ...n abrasive stainless steel cleaner immediately WARNING Do not use Ammonia based or abrasive cleaners on glass Do not attempt to clean glass when glass is hot PERIODIC CLEANING Refer to parts diagram f...

Page 28: ...n and or replace thermocouple 6 Burner does not stay lit a Burnerorificeclogged Cleanburnerorreplacemainburner orifice b Inlet gas pressure is too low Contact qualified service person 7 If burning at...

Page 29: ...be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number an...

Page 30: ...SEMBLY SUPPLY 1 1 20 P271 FITTING ORIFICE 1 1 21 R10808 AIR SHUTTER STAINLESS 1 1 22 P279 ORIFICE 14 1 0 22 P256 ORIFICE 41 0 1 23 B101848 GAS CONTROL KNOB 1 1 24 R7195 CONNECTOR BRASS MALE 1 1 25 R11...

Page 31: ...35008 1 0515 Page 31 OLL60FP PARTS VIEW 5 4 5 17 16 14 15 4 27 26 25 24 23 19 10 10 12 21 20 18 3 7 8 9 6 28 29 22 30 32 31 11 1 34 35 35 37 38 36 13 2 39 33 33...

Page 32: ...20 P271 FITTING ORIFICE 1 1 21 R10808 AIR SHUTTER STAINLESS 1 1 22 P279 ORIFICE 14 1 0 22 P256 ORIFICE 41 0 1 23 B101848 GAS CONTROL KNOB 1 1 24 R7195 BRASS CONNECTOR MALE 1 1 25 R11916 VALVE LP MANU...

Page 33: ...35008 1 0515 Page 33 OLL60SP PARTS VIEW 27 26 25 24 23 19 10 10 12 21 20 2 3 5 7 8 9 4 28 29 22 4 40 30 2 5 4 17 16 14 15 3 6 32 31 34 35 35 33 11 34 4 18 1 37 38 13 36 39 33...

Page 34: ...35008 1 0515 Page 34 Fireplace SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 35: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might...

Page 36: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Reviews: