background image

28743-0-0711

Page 21

35-7/16”

OR
38”

LOUVER

29-3/4”

5-15/16”

23-13/16”

10-1/8”

6-13/16”

PV-4H

(SHORT TOP

COVER KIT)

3-9/16”

16-15/16”

BAY WINDOW MANTIS SPECIFICATIONS - (continued)

35-7/16”

OR
38”

LOUVER

29-3/4”

5-15/16”

23-13/16”

PV-2H

(SLIM TOP

COVER KIT)

11-5/16”

3”

3-9/16”

6”

Fireplace Insert with Mantel Surround with PV-2H Slim Top Cover Kit

Figure 30

Fireplace Insert with Mantel Surround with PV-4H Short Top Cover Kit

Figure 31

Rear View

Figure 32

FLUE OUTLET

AIR INLET

ELECTRIC

CORD

13/16”

1”

7-5/16”

2-13/16”

1-7/16”

3-9/16”

1-1/2”

6-1/8”

FLEX HOSE

OPENING

Summary of Contents for Mantis BF28BM-5

Page 1: ...y other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neigh...

Page 2: ...s 18 Fireplace Mantis Clearance to Combustibles 19 Bay Window Mantis Specifications 20 21 Fireplace Mantis Specifications 22 23 Gas Connection Installation 24 Bay Window Mantis Log Set Installation In...

Page 3: ...WARNING Installation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning ma...

Page 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Page 5: ...IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the e...

Page 6: ...des Always consult with local authorities be fore installing any gas appliance Combustion and Ventilation Air U S National Fuel Gas Code NFPA 54 ANSI Z223 1 NFGC Air for Combustion and Ventilation Ele...

Page 7: ...Vent Pipe 1 1 2 inch diameter schedule 40 PVC pipe 40 feet maximum equivalent length ACCESSORIES Common Part Number Description TRW Wall Thermostat Wireless Remote FRBTP Battery Operated Remote with...

Page 8: ...ainst shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle purchase an adapt...

Page 9: ...y warnings exactly could result in serious injury death or property damage After gas piping to the heater is complete all connections must be tested for gas leaks This includes pipe connections at the...

Page 10: ...gulator vent outlet J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15 cm for appliances 10 000 Btu h 3 kW 9 in 23 cm for appliances...

Page 11: ...rom the center of the vent cap to the near est outside corner or obstruction is 12 inches The flue outlet must be at least 12 inches from any opening which flue gases could en ter the building See Fig...

Page 12: ...he total horizontal vent length of the flue system is 7 feet and the total vertical length is 27 feet The two 90 elbows are equivalent to 6 feet bringing the total to 40 feet Figure 4 is an example of...

Page 13: ...l to 40 feet Note The exhaust must be a minimum of 3 inches above the inlet air pipe The flue must be at least 12 inches from the roof line and it is recommended to be at least 12 inches above the max...

Page 14: ...nlet can be terminated with either a PTrap or two 90 elbows as shown in Figures 9 12 and 13 The Vertical Termina tion Cap Part number PVVTC can also be used H FLASHING REQUIRED H REQUIRED HEIGHT IS 12...

Page 15: ...HEIGHT IS 12 MINIMUM IT IS RECOMMENDED TO BE 12 ABOVE THE MAXIMUM EXPECTED SNOW LEVEL Installation of the Colinear Transition Plate 1 Attach the plate to chimney chase flat roof or outside wall with...

Page 16: ...um 12 5 8 minimum 17 7 8 minimum B 25 1 4 minimum 27 maximum when using PVE 1 or PVE 2 Surround Kits C 28 1 2 minimum 33 minimum recommended for service 34 1 2 maximum when using PVE 1 Surround Kit 37...

Page 17: ...B 25 1 4 minimum 27 maximum when using PVE 1 or PVE 2 Surround Kits C 28 1 2 minimum 33 minimum recommended for service 34 1 2 maximum when using PVE 1 Surround Kit 37 maximum when using PVE 2 Surroun...

Page 18: ...y Fireplace has been tested and approved for zero clearance to combustible materials It is recommended that clearances as listed above should be maintained to allow for removal of the product for serv...

Page 19: ...ace has been tested and approved for zero clearance to combustible materials It is recommended that clearances as listed above should be maintained to allow for removal of the product for servicing Fi...

Page 20: ...ater with Pedestal and Single Flue Adaptor Figure 27 28 25 1 4 27 3 4 FLUE OUTLET 16 15 16 17 5 8 3 9 16 9 0cm Heater without pedestal Figure 28 6 17 13 16 6 1 2 PVE 1 or PVE 2 SURROUND PVVK CFA FLEX...

Page 21: ...5 7 16 OR 38 LOUVER 29 3 4 5 15 16 23 13 16 PV 2H SLIM TOP COVER KIT 11 5 16 3 3 9 16 6 Fireplace Insert with Mantel Surround with PV 2H Slim Top Cover Kit Figure 30 Fireplace Insert with Mantel Surro...

Page 22: ...SS Contains surround hood and lower front Heater 35 Inch Surround Kit FFK28 BL CM HP SS Contains surround hood lower front Figure 35 Figure 36 Figure 33 Heater with Flex Vent PVVK CFA FLEX VENT KIT 2...

Page 23: ...AIR INLET ELECTRIC CORD FLEX HOSE OPENING 1 1 8 7 5 16 4 3 16 2 5 8 6 1 8 3 9 16 13 16 1 28 Heater 38 Inch Surround FIK28 BL CM HP SS Contains surround hood lower front Figure 37 Figure 38 4 8 Figure...

Page 24: ...line can be pushed back into the heater 3 Place rubber grommet that is supplied in hardware packet over the flexible gas line and secure in the hole in the back of the appliance Gas Connection In Wall...

Page 25: ...rs that are lo cated in the middle of the firebox The Middle Log D should be positioned as far to the right side of the firebox as pos sible 7 Locate the Front Right Log E in the right front corner of...

Page 26: ...t Figure 48 5 Place the Front Left Log E on left side of the firebox bottom The notch in bottom of Front Left Log fits over front Igniter The log should be positioned full forward See Figure 49 6 Plac...

Page 27: ...is connected to the white wire and the incoming hot line is con nected to the black wire The heater will not operate properly un less the polarity and ground are correct Instructions for connecting co...

Page 28: ...re place correctly See pages 25 to 26 The logs must be in the correct position or the heater will not operate correctly DO NOT light heater without the logs installed the heater will not operate prope...

Page 29: ...gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this la bel 2 Set the thermostat if used to the lowest setting 3 Turn off all electric power t...

Page 30: ...burner and back burner will flash 2 The inducer will activate immediately and will prove the pres sure switch within 16 seconds This will initiate the ignition sequence 3 The rear igniter HSI will en...

Page 31: ...e outlet side of the gas control Blower Operation The circulating air blower will automatically engage and increase in speed depending on the operation of the burners See Figure 56 In most circumstanc...

Page 32: ...his remote control SYSTEM offers the user a battery operated remote control that operates most millivolt gas valves used in some heater rated gas logs gas fireplaces and other gas heating appliances T...

Page 33: ...e THERMO MODE and DE SIRED room temperature Press the MODE key until the LCD screen shows the word ROOM then the remote is in the thermostatic mode Press and hold the SET key until the desired set tem...

Page 34: ...ed for longer battery life and maximum microprocessor performance IMPORTANT New or fully charged batteries are essential for proper operation of the remote receiver The remote receiver houses the micr...

Page 35: ...TRANSMITTER C S TX This ECS remote control has a COMMUNICATION SAFETY function built into its software It provides an extra margin of safety when the TRANSMITTER is out of the normal 20 foot operatin...

Page 36: ...rature drops below 120 F When the temperature drops below 120 F the beeping will cease providing the user has reset the THERMISTOR by pushing the MODE button to ON to operate the appliance either manu...

Page 37: ...ing manner Make sure the batteries are correctly installed in the RECEIVER One reversed battery will keep receiver from operating properly Check battery in Transmitter to make sure contacts are touchi...

Page 38: ...ngaged and is transfer ring the condensate there may be a noticeable hissing sound This is normal and the sound should persist for less than 30 sec onds The amount of condensate created will vary base...

Page 39: ...er To Deactivate Press the red button so it is not illuminated then the heater will return to normal operation Battery Operated Controls This unit is equipped with a factory installed wireless remote...

Page 40: ...wo door latches on both the left and right sides of the firebox 4 Carefully grab the glass frame and pull towards you Do not damage or remove the gasket from the door FIREPLACE MANTIS MODELS Removing...

Page 41: ...person Replacement Logs If for any reason a log should need replacement contact your Man tis dealer for correct replacement logs Replacement logs must be installed and positioned as outlined on Pages...

Page 42: ...DUCT 25 22780 INLET AIR DUCT ASSEMBLY 26 R10491 GASKET INLET AIR DUCT 27 21641 BRACKET ASSEMBLY THERMISTER SPRING CLIP INCLUDED 28 R4053 CLAMP DOOR 4 USED ON UNIT 29 22773 THERMISTER ASSEMBLY 30 R104...

Page 43: ...UBLE ROCKER 72 R8904 CIRCUIT BOARD 73 25226 CIRCUIT BOARD PLATE 74 R10759 RIBBON CABLE 75 R11043 CIRCUIT BOARD WIRE HARNESS 76 R10182 WIRE HARNESS 120V 77 R10183 WIRE HARNESS 12V 78 R10190 WIRE HARNES...

Page 44: ...28743 0 0711 Page 44 BAY WINDOW MANTIS PARTS VIEW 1 4A 3 2 4B 4C 5 6 9 7 30 28 5 21 27 24 28 19 11 12 9 34 16 14 26 25 22 17 8 13 36 18 35 23 15 94 93...

Page 45: ...45 BAY WINDOW MANTIS PARTS VIEW 69 67 32 61 50 47 48 53 54 53 51 60 20 56 55 48 47 80 52 39 40 41 42 38 45 46 89 85 86 87 88 81 84 78 77 76 90 44 43 49 37 82 70 71 64 79 63 62 57 59 30 10 74 75 68 29...

Page 46: ...ER 24V 25 26075 PUMP ASSEMBLY 28 25226 CIRCUIT BOARD PLATE 29 R8809 DOUBLE ROCKER SWITCH 30 R8840 WIRE HARNESS ASSEMBLY WITH ECONOMY SWITCH 31 R8904 CIRCUIT BOARD 32 26083 FRONT BURNER ASSEMBLY 33 260...

Page 47: ...R10383 LEFT TOP LOG 69 R10382 RIGHT TOP LOG 70 25216 BRACKET STANDOFF 2 REQUIRED 71 R2522 MAIN POWER SWITCH 73 R10610 WIRE HARNESS MAIN POWER SWITCH 74 R8795 GASKET SUMP 75 26119 HEADER COVER OUTLET 7...

Page 48: ...TIS PARTS VIEW 62 69 64 65 63 68 66 67 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 18 19 60 20 21 22 23 24 25 53 54 55 58 52 28 29 30 31 32 61 37 39 59 40 44 48 45 75 47 50 49 42 41 40 36 10 35 35 34 70 71 73...

Page 49: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 50: ...h the appliance Ready access to the appliance for service is the responsibility of the owner Travel diagnostic costs and freight charges on warranted parts to and from the factory is the responsibilit...

Page 51: ...28743 0 0711 Page 51 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 52: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: