background image

37134-4-0319

Page 13

1.   SToP!

   Read the safety information above.

2.  Turn off all electric power to the appliance.

3.   This appliance is equipped with an ignition device which 

automatically lights the pilot.  Do not try to light the pilot 

by hand.

ON

OFF

IGNITOR

CONTROL

GAS FLOW

GAS VALVE SHOWN IN OFF POSITION

HONEYWELL IP SMART VALVE

4.  Remove front panel door.

5.   Slide  gas control switch to "oFF."
6.   Wait ten (10) minutes   to clear out any gas.  Then smell 

for gas, including near the floor.  If you smell gas, SToP! 

Follow "B" in the safety information above.  If you don't 

smell gas, go to the next step.

7.  Slide gas control switch to "oN".
8.   replace front panel  door. 
9.   Turn on all electric power to the appliance.
10.  If the appliance will not operate, follow the instructions 

"To TURn oFF GAS To APPLIAnCE" and  call your service 

technician or gas supplier.

A.   This appliance is equipped with an ignition device which 

automatically lights the pilot.  

 Do not try to light the pilot by hand.
B.   BEForE oPErATING  smell all around the appliance area 

for gas.  Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.

 

WHAT To Do IF You SMEll GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; 

 

do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor's 

phone.  Follow the gas supplier's instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

C.   Use only your hand to slide the gas control knob.  never 

use tools. Force or attempted repair may result in a fire 

or explosion.

D.   Do not use this appliance if any part has been under water.  

Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system 

and any gas control which has been under water.

INTErMITTENT PIloT (IP) -lIGHTING INSTrucTIoNS

For Your SAFETY rEAD BEForE oPErATING

oPErATING INSTrucTIoNS

1.   Turn off all electric power to the appliance if service is to 

be performed.

2.   Remove front panel door.

3.   Slide gas control switch to "oFF." 
4.   replace front panel door.

To TurN oFF GAS To APPlIANcE

WArNING 

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury or loss of life.

Summary of Contents for FAW40IPXLP-1

Page 1: ...operty damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try t...

Page 2: ...d Tile If this appliance is installed directly on carpeting tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full wid...

Page 3: ...inal venting system may no longer be sized to properly vent the attached appliances Instructions shall also indicate effects of an improperly sized venting system formation of condensate leakage spill...

Page 4: ...can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a cl...

Page 5: ...n in a Confined Space A confined space is an area with volume less than 50 cubic feet per 1 000 Btuh of the combined input rates of all appliances drawing combustion air from that space Small areas su...

Page 6: ...in a horizontal distance of 10 feet 3m 2 This furnace must not be connected to a chimney flue serving a separate solid fuel burning appliance 3 UninsulatedSingle WallMetalPipeshallnotbeusedoutdoors in...

Page 7: ...ide outlet wall plate over outer boot pass the outer boot through the wall and attach side wall plate to furnace side of wall with 2 10 x 1 1 2 38mm provided screws 5 Attach outer boot to the cabinet...

Page 8: ...ehind the furnace Attach furnace to wall at the outer casing top with 2 toggle bolts provided and to floor at the outer casing bottom with 2 10 x 1 1 2 38mm screws provided Gas Supply Check all local...

Page 9: ...cover screw on the control valve Figure 9 and turn the adjustment screw clockwise to reduce flame Replace pilot cover screw to eliminate gas leakage Propane Gas will not require adjustment After use...

Page 10: ...located on the draft diverter 3 Replace front panel If the manual reset vent safety switch continues to shut off the gas flow to the main burners a qualified service person must be contacted to inspe...

Page 11: ...he same terminal it was on Terminal should have a light spark Do not short across terminals as it will burn out the GAS CONTROL 2 To check for line voltage to furnace remove front panel and short acro...

Page 12: ...rn off all electric power to the appliance 3 Remove control access panel front panel 4 Turn gas control knob clockwise to OFF GAS CONTROL SHOWN IN OFF POSITION 5 Wait ten 10 minutes to clear out any g...

Page 13: ...iance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any e...

Page 14: ...ition OFF Wait for Flame Signal to Disappear Pilot Valve Closes Ignition OFF Main Pilot Valves Close Flame Lost More Than 5 Times in One Call for Heat 5 Minute Retry Delay 3 Second Flame Recycle Delay...

Page 15: ...Flowing Wait to Assure Pilot Gas Tubing is Purged Measure Voltage Between 24V Hot and 24V Common Leads to SmartValve Control Must Measure at Least 19 5 VAC with Igniter Powered See Inset A to Identif...

Page 16: ...31 P8851 ORIFICE Natural 3 REQUIRED 31 P8860 ORIFICE Propane 3 REQUIRED 32 DV1236 MANIFOLD 33 DV1258 CASING FRONT 34 P112 MANIFOLD UNION 35 R1109 BUSHING 3 8 x 1 2 35 R9502 BUSHING 3 8 x 3 4 NATURAL I...

Page 17: ...37134 4 0319 Page 17...

Page 18: ...ase and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Mode...

Page 19: ...le cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from t...

Page 20: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Reviews: