41978-2-0321
Page 32
VENT SYSTEM IDENTIFICATION
Begin the vent system installation by selecting the type of venting
to be installed and the path it will take. Verify clearances are met
throughout the path of the venting system.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to
the “Special Vent Systems” section in this manual to determine
what systems are acceptable.
Check all clearances and venting components. Identify if any
problems exist in the vent system. Use
Figure 39
on page 33 for top
venting to eliminate issues after installation. Check pipe diameter on
vent system and fireplace to verify the size is the same.
NOTICE
: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
SPECIAL VENTING COMPONENTS (DURAVENT)
See Empire Comfort Systems Retail Price List for Duravent part
numbers and pricing.
SPECIAL DV VENT KITS
Available from Empire Comfort Systems, Inc. Dealers"
DVVK-4VP
(DVVK-4V)
Direct-Vent Fireplace Vent Kit - Vertical, includes
46DVA-VCH, 46DVA-F6 and 46DVA-SC
DVVK-4TP
(DVVK-4T)
Direct-Vent Fireplace Vent Kit - For top vent,
thru-the-wall, 8 to 11 inch wall thickness,
includes 46DVA-HC, 46DVA-E90, 46DVA-09,
46DVA-08A and 46DVA-WT
DVVK-4TSP
(DVVK-RTS)
Direct-Vent Fireplace Vent Kit - For top vent,
thru-the-wall, 5 to 7 inch wall thickness,
includes 46DVA-HC, 46DVA-E90, 46DVA-06
and 46DVA-WT
DVVK-4FV
Vertical Flex Vent Kit - 4 inch x 7 inch - Requires
the use of SD46DVAFCFX7.
VIB6A
Vertical Inlet Baffle Kit - For 6-5/8 inch Diameter.
VIB7A
Vertical Inlet Baffle Kit - For 7 inch Diameter.
VENT SYSTEMS
•
Simpson Duravent
®
GS 4" - 6⅝"
•
Selkirk Direct-Temp
®
4" - 6⅝"
•
ICC Excel Direct
®
4" - 6⅝"
•
Empire Flexvent Kit DVVK-4F
•
Empire Flexvent Kit DVVK-4FV Vertical
Flex Vent Kit
The following vent systems are acceptable for use with the DVL36BP and DVL46BP series fireplaces:
Figure 38
FLASHING
STORM
COLLAR
VERTICAL
TERMINATION
(THREE 90°
ELBOWS MAX)
WALL
THIMBLE
HORIZONTAL
TERMINATION
(THREE 90°
ELBOWS MAX)
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING
FIRE STOP
WALL STRAP
PIPE LENGTH
THIMBLE
SPACER
VERTICAL
TERMINATION
(THREE 90°
ELBOWS MAX)
STORM
COLLAR
FLASHING
HORIZONTAL
TERMINATION
(THREE 90°
ELBOWS MAX)
THIMBLE
SPACER
WALL
THIMBLE
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING
FIRE STOP
WALL STRAP
PIPE LENGTH