35431-0-0315
Page 9
Introduction
Always consult your local Building Department regarding regula-
tions, codes or ordinances which apply to the installation of a
vented decorative gas log set in a solid-fuel burning fireplace.
This appliance is only for use with the type of gas indicated on
the rating plate.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card
supplied with the fireplace.
3. Installer should show owner how to start and operate the
fireplace.
WARNING
Any change to this appliance or its controls can be dangerous.
Improper installation or use of the appliance can cause serious
injury or death from fire, burns, explosion or carbon monoxide
poisoning.
INTRODUCTION
General Information
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model No., Serial
No. and type of gas. This information can be found on the data
plate supplied with the burner.
Notice
:
During initial use of the logs and branches you will detect
an odor as the logs and branches are cured. This is normal.
WARNING
A fireplace screen must be in place when this appliance is
in operation. Unless other provisions for combustion air are
provided, the screen shall have an opening(s) for introduction
of combustion air.
• Turn off gas supply to fireplace or firebox.
• Have the fireplace floor and chimney professionally cleaned to
remove ashes, soot, creosote or other obstructions.
Have this cleaning performed annually after installation.
• Seal any fresh air vents or ash clean-out doors located on floor
or wall of fireplace. If not, drafting may cause pilot outage or
sooting. Use a heat-resistant sealant. Do not seal chimney flue
damper.
Installing Damper Clamp
Remove all ashes or other debris from the fireplace. If the fireplace
is equipped with an ash dump be sure to seal the door with furnace
cement or high temperature silicone. Be sure to check the damper
for proper operation and verify that the flue passageway is open.
Attach damper clamp to the vent damper and tighten hold down bolt.
Place the clamp over the lip of the damper and tighten the hold
down bolt until the clamp is securely attached to the damper. This
will prevent the damper from accidentally closing.
DAMPER CLAMP
DAMPER
TYPICAL FIREPLACE
Figure 1
FIREPLACE PREPARATION