background image

WARNING

FIRE OR EXPLOSION HAZARD

If the information in this manual is not 

followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life.

—  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do 

not use any phone in your building.

•  Leave the building immediately.

•  Immediately call your gas supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

•  If you cannot reach your gas supplier, 

call the fire department.

—  Installation and service must be 

performed by a qualified installer, 

service agency or the gas supplier.

INSTALLER: 

Leave this manual with the appliance.

CONSUMER: 

Retain this manual for future reference.

This is an unvented gas-fired heater. It uses air 

(oxygen) from the room in which it is installed. 

Provisions  for  adequate  combustion  and 

ventilation air must be provided. 

WaTer VaPor: a By-ProDucT oF 

UNvENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. 

an unvented room heater produces approximately 

one (1) ounce (30ml) of water for every 1,000 Btu 

(.3KW's) of gas input per hour. 

This appliance may be installed in an 

aftermarket, permanently located, manufactured 

(mobile)  home,  where  not  prohibited  by  local 

codes.

This appliance is only for use with the type of 

gas indicated on the rating plate. This appliance 

is not convertible for use with other gases.

WARNING

If  not  installed,  operated  and  maintained  in 

accordance with the manufacturer's instructions, 

this product could expose you to substances in 

fuel or from fuel combustion which can cause 

death or serious illness.

UNvENTED 

ROOM HEATER

 

MODELS

BF-10W-1  BF-20W-1 BF-30W-1

GAS-FIRED

UL FILE NO. MH46389

INSTALLATION INSTRUCTIONS

Summary of Contents for BF-10W-1

Page 1: ...l for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Water Vapo...

Page 2: ...n and Ventilation Air 6 Gas Supply 7 Clearances 8 Optional Floor Stand Installation 8 Wall Mount Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Important Soot Prevention...

Page 3: ...to replace any part of the control system and any gas control which has been under water Keep appliance area clear and free from combustible materials gasolineandotherflammablevaporsandliquids Warning...

Page 4: ...ghts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorpt...

Page 5: ...ow to start and operate unvented room heater Always consult your local Building Department regarding regula tions codes or ordinances which apply to the installation of an unvented room heater This ap...

Page 6: ...F 20W is 20 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu per hour formula the minimum area that is an unconfined space for installation of the BF 20W is 1 000 cubic feet 50 cubic feet x 2...

Page 7: ...by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which co...

Page 8: ...oves The protection is for rugs that are extremely thick and light colored tile BF 30W Figure 4 FLOOR 36 914mm MIN 5 MIN 127mm 2 MIN 51mm SIDE WALL CEILING 5 MIN 127mm BF 10W and BF 20W Figure 3 FLOOR...

Page 9: ...behind the heat shield b When replacing reflector be sure the top lip of reflector goes in front of the heat shield 3 Connect the gas line BF 10 and BF 20 18 457mm 14 356mm 2 51mm 2 51mm 1 3 32 28mm 1...

Page 10: ...when the safety magnet in the gas control is de energized Pilot can now be relighted Repeat steps 4 through 8 10 Turn gas control knob counterclockwise to HI 11 Turn on all electric power to applianc...

Page 11: ...mulation of dust lint or spider webs If necessary clean interior of casing assembly with a vacuum cleaner or apply air pressure Do not damage any components within casing assembly when you are cleanin...

Page 12: ...s HI setting The hydraulic thermostat bulb which is located at the casing assembly bottom adjusts the main burner flame between minimum input and maximum input BF 30W The gas control modulates from a...

Page 13: ...30TW is installed in heater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Remove upper louver from casing assembly 2 screws 6 If installed rem...

Page 14: ...ompletely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 10 Step 9 c Thermocouple lead not tightened into gas control tighten thermocouple lea...

Page 15: ...EFT 22 40465 BURNER BF 10W BF 20W 22 39834 BURNER BF 30W 23 10424 AIR SHUTTER REAR BF 10W ONLY 24 10461 BURNER BRACKET RIGHT 25 P 214 MAIN BURNER ORIFICE BF 10W NATURAL 25 P 193 MAIN BURNER ORIFICE BF...

Page 16: ...39892 4 0719 Page 16 7 14 11 10 13 16 15 33 8 9 4 7 6 1 2 5 3 17 19 18 20 34 28 37 35 36 42 41 38 40 39 25 30 21 22 32 31 29 27 23 24 26 PARTS VIEW...

Page 17: ...at shield Insert the blower housing into the top portion of the heater by pivoting the blower housing upward 90 Attach the blowerhousingtothecasingassemblywith 4 screwsprovided with the optional blowe...

Page 18: ...lect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to the heater 2 Tur...

Page 19: ...oducts 10 East Route 36 West Long Branch NJ 07764 Phone 732 870 8809 Toll Free 800 755 8809 Fax 732 870 8811 Website www eastcoastenergy com Parts Heater Hearth and Grills MASTER PARTS DISTRIBUTOR LIS...

Page 20: ...the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should...

Reviews: