background image

Page 4

VFHS-20/10

Some people cannot smell well. Some people cannot smell the
odor of the chemical put into the gas. You must find out if you
can smell the odorant in propane.
 Smoking can decrease your
ability to smell. Being around an odor for a time can affect your
sensitivity or ability to detect that odor. Sometimes other odors
in the area mask the gas odor. People may not smell the gas odor
or their minds are on something else. Thinking about smelling a
gas odor can make it easier to smell.

The odorant in LP-gas is colorless, and it can fade under
some circumstances.
 For example, if there is an underground
leak, the movement of the gas through soil can filter the odorant.
Odorants in LP-Gas also are subject to oxidation. This fading can

by point with the members of your household. Someday
when there may not be a minute to lose, everyone's safety will
depend on knowing exactly what to do. If, after reading the
following information, you feel you still need more informa-
tion, please contact your gas supplier.

Propane (LP-Gas) is a flammable gas which can cause fires
and explosions. In its natural state, propane is odorless and
colorless. You may not know all the following safety precau-
tions which can protect both you and your family from an
accident. Read them carefully now, then review them point

occur if there is rust inside the storage tank or in iron gas pipes.

The odorant in escaped gas can adsorb or absorb onto or into
walls, masonry and other materials and fabrics in a room. That
will take some of the odorant out of the gas, reducing its odor
intensity.

LP-Gas may stratify in a closed area, and the odor intensity could
vary at different levels. Since it is heavier than air, there may be
more odor at lower levels. Always be sensitive to the slightest
gas odor. If you detect any odor, treat it as a serious leak.
Immediately go into action as instructed earlier.

Learn to recognize the odor of LP-gas. Your local LP-Gas
Dealer can give you a "Scratch and Sniff" pamphlet. Use it to
find out what the propane odor smells like. If you suspect that
your LP-Gas has a weak or abnormal odor, call your LP-Gas
Dealer.

If you are not qualified, do not light pilot lights, perform
service, or make adjustments to appliances on the LP-Gas
system. If you are qualified, consciously think about the odor
of LP-Gas prior to and while lighting pilot lights or perform-
ing service or making adjustments.

Sometimes a basement or a closed-up house has a musty
smell that can cover up the LP-Gas odor. Do not try to light
pilot lights, perform service, or make adjustments in an area
where the conditions are such that you may not detect the
odor if there has been a leak of LP-Gas.

Odor fade, due to oxidation by rust or adsorption on walls of
new cylinders and tanks, is possible. Therefore, people
should be particularly alert and careful when new tanks or
cylinders are placed in service. Odor fade can occur in new
tanks, or reinstalled old tanks, if they are filled and allowed

to set too long before refilling. Cylinders and tanks which
have been out of service for a time may develop internal rust
which will cause odor fade. If such conditions are suspected
to exist, a periodic sniff test of the gas is advisable. If you
have any question about the gas odor, call your LP-gas
dealer. A periodic sniff test of the LP-gas is a good safety
measure under any condition.

If, at any time, you do not smell the LP-Gas odorant and you
think you should, assume you have a leak. Then take the same
immediate action recommended above for the occasion when
you do detect the odorized LP-Gas.

If you experience a complete "gas out," (the container is
under no vapor pressure), turn the tank valve off immedi-
ately. If the container valve is left on, the container may draw
in some air through openings such as pilot light orifices. If
this occurs, some new internal rusting could occur. If the
valve is left open, then treat the container as a new tank.
Always be sure your container is under vapor pressure by
turning it off at the container before it goes completely empty
or having it refilled before it is completely empty.

Do not operate electric switches, light matches, use your
phone. Do not do anything that could ignite the gas.

Get everyone out of the building, vehicle, trailer, or area. Do
that IMMEDIATELY.

Close all gas tank or cylinder supply valves.

LP-Gas is heavier than air and may settle in low areas such
as basements. When you have reason to suspect a gas leak,
keep out of basements and other low areas. Stay out until
firefighters declare them to be safe.

Use your neighbor's phone and call a trained LP-Gas service
person and the fire department. Even though you may not
continue to smell gas, do not turn on the gas again. Do not re-
enter the building, vehicle, trailer, or area.

Finally, let the service man and firefighters check for
escaped gas. Have them air out the area before you return.
Properly trained LP-Gas service people should repair the
leak, then check and relight the gas appliance for you.

SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.

That's your signal to go into immediate action!

SAFETY INFORMATION FOR USERS OF LP-GAS

Summary of Contents for VFHS-10T-1

Page 1: ...nstructions If you cannot reach your gas sup plier call the fire department Installation and service must be per formedbyaqualifiedinstaller service agency or the gas supplier This is an unvented gas...

Page 2: ...11 Log Placement 12 Placement of Glowing Embers Rock Wool 12 Operation Instructions Flame Appearance 13 VFHS 20R Lighting Instructions 14 VFHS 20 10T Lighting Instructions 15 Pilot Flame Characterist...

Page 3: ...high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room with the appliance Do not place clothing...

Page 4: ...service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of ne...

Page 5: ...d at the rate of 4 percent for each 1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size Instructions to Installer 1 Installer must leave inst...

Page 6: ...regate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered...

Page 7: ...t the space is an unconfined space You will need no additional fresh air ventilation WARNING You must provide additional ventilation air in a confined space VENTILATION AIR Ventilation Air From Inside...

Page 8: ...Z21 45 Assembled Flexible Appliance Connectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction Pressure Testing of the Gas Supp...

Page 9: ...lace opening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the fireplace opening to the ceiling should not be less than 30 inches Mantel Clearances...

Page 10: ...astboard into right mantel side Breastboard will rest on fireplace top and in front of nailing flange Attention Placing the breastboard in front of nailing flange will secure the fireplace 6 Placeleft...

Page 11: ...two 2 10 x 1 2 screws for each nailing flange 2 Gas line connections must be made at this time When facing the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert fi...

Page 12: ...rear portion of burner A thin layer of rock wool should be placed under open space between the right and left middle logs Rock wool should not be placed in the area of the pilot assembly 1 Remove shi...

Page 13: ...Do not place a blower inside the burner area of the firebox Ceiling fans may create drafts that alter flame patterns Sooting and improper burning will result During manufacturing fabricating and ship...

Page 14: ...le Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If appli cable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure t...

Page 15: ...ot force TO TURN OFF GAS TO APPLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7...

Page 16: ...ect appearance of pilot flame Figure 17 If pilot flame pattern is incorrect as shown in Figure 17 See Troubleshooting page 19 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot Figure 18 Whe...

Page 17: ...orifice fitting 8 Remove air shutter from orifice fitting 9 ForNaturalgasonly remove20 000Btumainburnerorifice marked 49 from orifice fitting and replace with 10 000 Btu VFHS 20R Main Burner Operatio...

Page 18: ...k Red wires to attach optional components Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range Remote Receiver Use...

Page 19: ...t assembly or get it serviced g Gas regulator setting is not correct Replace gas regulator 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press...

Page 20: ...COVER PLATE 37 R 3436 REMOTE OFF ON SWITCH NOT SHOWN 11458 TUBING VALVE TO PILOT NOT SHOWN 11459 TUBING VALVE TO BURNER NOT SHOWN R 4579D SWITCH WIRE HARNESS NOT SHOWN P 263 NIPPLE 7 1 2 VFHS 20 10T...

Page 21: ...Page 21 VFHS 20 10 PARTS VIEW...

Page 22: ...ges of the 2 side brick liners Attach liner mounting brackets to outer casing with 4 four 10 x 1 2 screws provided in optional brick liner kit 6 Replace logs into burner assembly Refer to Log Placemen...

Page 23: ...itemotor Startone 1 8x1 2 Phillipsscrewinto top motor mounting bracket and gasket adjacent to motor Align and attach blower assembly to outer casing side See Figure 2 10 Snap Heyco into blower shield...

Page 24: ...INSTRUCTIONS continued Figure 3 Figure 4 cover on burner assembly Insert blower shield front adjacent to blower motor and blower shield side Align clearance hole on blower shield front with left fron...

Page 25: ...Step 6 Tighten two 2 10 x 1 2 screws at interior top of inner casing that were loosened in Step 6 28 Attach burner assembly to inner bottom with three 3 10 x 1 2 screws from Step 5 29 Attach rear log...

Page 26: ...liance cord plug can be plugged into the adapter and be electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous oper...

Page 27: ...5 REMOTE CONTROL 2 R 3486 EXTENSION CORD 3 R 3487 CONTROL UNIT FRBTC 1 BATTERY OPERATED REMOTE CONTROL WITH THERMOSTAT 1 R 3516 REMOTE CONTROL 2 R 3517 REMOTE CONTROL HOLDER 3 R 3518 CONTROL UNIT FRBC...

Page 28: ...Page 28 VFHS 20 10 SERVICE NOTES Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62222 0529 Web Site www empirecomfort com E mail info empirecomfort com...

Reviews: