VFHS-20/10

The VFHS-20/10T gas control maximum and minimum
inputs are listed below.

OFF is the OFF position.

PILOT is the PILOT position.

VFHS-20/10T

Max.

20,000 BTUH

Min.

7,000 BTUH

VFHS-20/10T can be converted to 10,000 BTU for Bedroom
Installation
Max.

10,000 BTUH

Min.

7,000 BTUH

Cleaning and Maintenance/Pilot

Oxygen Depletion Sensor Pilot (Figure 21)
When the pilot has a large yellow tip flame, clean the Oxygen
Depletion Sensor as follows:

1. Clean the ODS pilot by loosening nut B from the pilot

tubing. When this procedure is required, grasp nut A with
an open end wrench.

2. Blow air pressure through the holes indicated by the arrows.

This will blow out foreign materials such as dust, lint and
spider webs. Tighten nut B also by grasping nut A.

Warning:
Never use needles, wires, or similar cylindrical objects
to clean the pilot to avoid damaging the calibrated ruby
that controls the gas flow.

Figure 21

MAIN BURNER AND THERMOSTAT OPERATION

For installation in a bedroom the VFHS-20T, 20,000 Btu input
must be converted to a VFHS-10T 10,000 input fireplace.

Attention: Main burner orifice for conversion to VFHS-10T is
located in your Owner's Envelope.

Bedroom Installation: VFHS-10T Only
The bedroom must be an unconfined space. ANSI Z223.1/NFPA54
defines an unconfined space as “a space whose volume is not less
than 50 cubic feet per 1,000 Btu per hour (4.8m

3

 per kw) of the

aggregate input rating of all appliances installed in that space.”

Refer to "Provisions for Adequate Combustion and Ventilation
Air," Page 6.
Instructions for Conversion of a VFHS-20T into a VFHS-10T:

1. If installed, turn OFF gas supply to fireplace.
2. Lift upward to remove screen front.
3. Remove logs from fireplace.
4. Remove rear log support from inner casing [three (3) 10 x 1/2"

screws].

5. Disconnect supply tubing from orifice fitting.
6. Remove air shutter and orifice fitting from venturi (throat) of

main burner by removing one (1) Phillips screw.

7. For Natural gas only, remove coupling from orifice fitting.
8. Remove air shutter from orifice fitting.
9. For Natural gas only, remove 20,000 Btu main burner orifice

marked 49 from orifice fitting and replace with 10,000 Btu

VFHS-20R Main Burner Operation
The gas control modulates from a minimum input of 14,000
BTU/HR (LO setting) to a maximum input of 20,000 BTU/HR
(HI setting).

Cleaning and Maintenance / Main Burner
Warning
: Turn off heater and let cool before cleaning.

Caution: You must keep control areas, burner and circulating air
passageways of heater clean. Inspect these areas of heater before
each use. Have heater inspected yearly by a qualified service
person. Heater may need more frequent cleaning due to excessive
lint from carpeting, bedding materials, etc.

Logs
Be careful cleaning and handling logs so as not to damage them.
If logs break or fall apart in handling, spray the broken pieces and
fibers with water, sweep up and discard.

VFHS-20T CONVERSION TO VFHS-10T FOR BEDROOM INSTALLATION

main burner orifice marked 1.30mm.

9. For Propane (LP) gas only, remove 20,000 Btu, main burner

orifice marked 55 from orifice fitting and replace with 10,000
Btu main burner orifice marked 64.

10. Replace air shutter onto orifice fitting.
11. For Natural gas only, replace coupling onto orifice fitting.
12. Attach air shutter and orifice fitting onto venturi (throat) of

main burner with one (1) Phillips screw from Step 6.
Attention: Air shutter will have a 1/16" opening on Natural
gas. Air shutter will be fully open on Propane (LP) gas.

13. Attach supply tubing onto orifice fitting.
14. Attach rear log support to inner casing with three (3) 10 x

1/2" screws from Step 4.

15. Turn on gas supply to fireplace and check all gas connections

for leaks with soap solution, watching for bubbles on all gas
connections.

16. Install logs into fireplace, refer to "Log Placement", Page 12.
17. Replace screen front onto fireplace.
18. Check main burner flame for proper flame characteristics.

Refer to "Operation Instructions/Flame Appearance, Page
13.

19. Refer to rating plate in order to check box for which

installation applies, either 20,000 or 10,000 Btu input.

20. Conversion from 20,000 Btu to 10,000 Btu input fireplace is

completed.

Summary of Contents for VFHS-10T-1

Page 1: ...nstructions If you cannot reach your gas sup plier call the fire department Installation and service must be per formedbyaqualifiedinstaller service agency or the gas supplier This is an unvented gas...

Page 2: ...11 Log Placement 12 Placement of Glowing Embers Rock Wool 12 Operation Instructions Flame Appearance 13 VFHS 20R Lighting Instructions 14 VFHS 20 10T Lighting Instructions 15 Pilot Flame Characterist...

Page 3: ...high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room with the appliance Do not place clothing...

Page 4: ...service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of ne...

Page 5: ...d at the rate of 4 percent for each 1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size Instructions to Installer 1 Installer must leave inst...

Page 6: ...regate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered...

Page 7: ...t the space is an unconfined space You will need no additional fresh air ventilation WARNING You must provide additional ventilation air in a confined space VENTILATION AIR Ventilation Air From Inside...

Page 8: ...Z21 45 Assembled Flexible Appliance Connectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction Pressure Testing of the Gas Supp...

Page 9: ...lace opening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the fireplace opening to the ceiling should not be less than 30 inches Mantel Clearances...

Page 10: ...astboard into right mantel side Breastboard will rest on fireplace top and in front of nailing flange Attention Placing the breastboard in front of nailing flange will secure the fireplace 6 Placeleft...

Page 11: ...two 2 10 x 1 2 screws for each nailing flange 2 Gas line connections must be made at this time When facing the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert fi...

Page 12: ...rear portion of burner A thin layer of rock wool should be placed under open space between the right and left middle logs Rock wool should not be placed in the area of the pilot assembly 1 Remove shi...

Page 13: ...Do not place a blower inside the burner area of the firebox Ceiling fans may create drafts that alter flame patterns Sooting and improper burning will result During manufacturing fabricating and ship...

Page 14: ...le Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If appli cable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure t...

Page 15: ...ot force TO TURN OFF GAS TO APPLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7...

Page 16: ...ect appearance of pilot flame Figure 17 If pilot flame pattern is incorrect as shown in Figure 17 See Troubleshooting page 19 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot Figure 18 Whe...

Page 17: ...orifice fitting 8 Remove air shutter from orifice fitting 9 ForNaturalgasonly remove20 000Btumainburnerorifice marked 49 from orifice fitting and replace with 10 000 Btu VFHS 20R Main Burner Operatio...

Page 18: ...k Red wires to attach optional components Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range Remote Receiver Use...

Page 19: ...t assembly or get it serviced g Gas regulator setting is not correct Replace gas regulator 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press...

Page 20: ...COVER PLATE 37 R 3436 REMOTE OFF ON SWITCH NOT SHOWN 11458 TUBING VALVE TO PILOT NOT SHOWN 11459 TUBING VALVE TO BURNER NOT SHOWN R 4579D SWITCH WIRE HARNESS NOT SHOWN P 263 NIPPLE 7 1 2 VFHS 20 10T...

Page 21: ...Page 21 VFHS 20 10 PARTS VIEW...

Page 22: ...ges of the 2 side brick liners Attach liner mounting brackets to outer casing with 4 four 10 x 1 2 screws provided in optional brick liner kit 6 Replace logs into burner assembly Refer to Log Placemen...

Page 23: ...itemotor Startone 1 8x1 2 Phillipsscrewinto top motor mounting bracket and gasket adjacent to motor Align and attach blower assembly to outer casing side See Figure 2 10 Snap Heyco into blower shield...

Page 24: ...INSTRUCTIONS continued Figure 3 Figure 4 cover on burner assembly Insert blower shield front adjacent to blower motor and blower shield side Align clearance hole on blower shield front with left fron...

Page 25: ...Step 6 Tighten two 2 10 x 1 2 screws at interior top of inner casing that were loosened in Step 6 28 Attach burner assembly to inner bottom with three 3 10 x 1 2 screws from Step 5 29 Attach rear log...

Page 26: ...liance cord plug can be plugged into the adapter and be electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous oper...

Page 27: ...5 REMOTE CONTROL 2 R 3486 EXTENSION CORD 3 R 3487 CONTROL UNIT FRBTC 1 BATTERY OPERATED REMOTE CONTROL WITH THERMOSTAT 1 R 3516 REMOTE CONTROL 2 R 3517 REMOTE CONTROL HOLDER 3 R 3518 CONTROL UNIT FRBC...

Page 28: ...Page 28 VFHS 20 10 SERVICE NOTES Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62222 0529 Web Site www empirecomfort com E mail info empirecomfort com...

Reviews: