36092-11-0820
Page 17
Figure 15
NOTICE
: Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not exceed 20 feet
with a minimum vertical run of 8 feet from fireplace floor. See details in Venting Section.
NOTICE
: Inuslate to applicable codes when installing this fireplace against an exterior wall.
A minimum clearance of 6 inches must be maintained from the perpendicular wall to the firebox opening of the fireplace, if the fireplace
is installed in the room divider or peninsula room divider positions.
LOCATING FIREPLACE