36092-10-0619
Page 6
SPECIFICATIONS
NATURAL GAS
PROPANE GAS
Peninsula Models
See-Thru Models
Peninsula Models
See-Thru Models
Input BTU/Hr Maximum
34,000
34,000
32,000
32,000
Input BTU/Hr Minimum
23,000
23,000
26,500
26,500
KWH (Maximum)
9.96
9.96
9.38
9.38
KWH (Minimum)
6.74
6.74
7.76
7.76
Orifice
#33
#33
#51
#51
Air Shutter Opening*
3/16in
(1/8in w/40ft. Vertical
Vent, flue restrictor
installed)
3/16in
(1/8in w/40ft. Vertical
Vent, flue restrictor
installed)
FULLY OPEN
FULLY OPEN
Height without standoff
39-1/2in
39-1/2in
39-1/2in
39-1/2in
Width
42-1/4in
45-1/2in
42-1/4in
45-1/2in
Depth
24in
24in
24in
24in
Gas Inlet Shutoff
Valve (pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
Venting
5” x 8”, See Page 26
5” x 8”, See Page 26
5” x 8”, See Page 26
5” x 8”, See Page 26
*NOTICE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
GAS SUPPLY PRESSURES
Gas Type
Maximum
Minimum
Manifold
Natural
14
4.5
3.5
Propane
14
11
10
Summary of Contents for MILLIVOLT DVCP36PP30N
Page 45: ...LOG PLACEMENT LSU24SPF 36092 10 0619 Page 45...
Page 66: ...36092 10 0619 Page 66 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Page 67: ...36092 10 0619 Page 67 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Page 71: ...36092 10 0619 Page 71 This page intentionally left blank...