
36092-10-0619
Page 17
Figure 15
NOTICE
: Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not exceed 20 feet
with a minimum vertical run of 8 feet from fireplace floor. See details in Venting Section.
NOTICE
: Inuslate to applicable codes when installing this fireplace against an exterior wall.
A minimum clearance of 6 inches must be maintained from the perpendicular wall to the firebox opening of the fireplace, if the fireplace
is installed in the room divider or peninsula room divider positions.
LOCATING FIREPLACE
Summary of Contents for MILLIVOLT DVCP36PP30N
Page 45: ...LOG PLACEMENT LSU24SPF 36092 10 0619 Page 45...
Page 66: ...36092 10 0619 Page 66 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Page 67: ...36092 10 0619 Page 67 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Page 71: ...36092 10 0619 Page 71 This page intentionally left blank...