background image

Page 1

B-VENT ZERO CLEARANCE

GAS FIREPLACE

mILLIVOLT mOdELS:

BVD34FP30(F,L)N-3

BVD36FP30(F,L)N-2

BVP42FP30(F,L)N-2

IPI ELECTRONIC mOdELS:

BVD34FP70(F,L)N-1

BVD36FP70(F,L)N-1

BVP42FP70(F,L)N-1

NOT INTENdEd FOR USE AS A PRImARY HEAT 

SOURCE. This appliance is tested and approved as 

either supplemental room heat or as a decorative 

appliance. It should not be factored as primary heat 

in residential heating calculations.
This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases, unless a certified 

kit is used.

WARNING

FIRE OR EXPLOSION HAZARd

Failure to follow safety warnings exactly 

could result in serious injury, death or 

property damage.

— do not store or use gasoline or other 

flammable vapors and liquids in the vi

-

cinity of this or any other appliance.

—  WHAT TO dO IF YOU SmELL GAS

•  Do not try to light any appliance.

• 

do not touch any electrical switch; do 

not use any phone in your building.

•  Leave the building immediately.

•  Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

•  If you cannot reach your gas suppli

-

er, call the fire department.

— Installation and service must be per-

formed  by  a  qualified  installer,  service 

agency or the gas supplier.

HOT GLASS

DO NOT TOUCH

NEVER

WILL

CAUSE BURNS.

GLASS

UNTIL COOLED.

ALLOW CHILDREN

TO TOUCH GLASS.

WARNING

A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.

INSTALLER: 

Leave this manual with the appliance.

CONSUmER: 

Retain this manual for future reference.

INSTALLATION INSTRUCTIONS

ANd OWNER'S mANUAL

UL FILE NO. 

MH45034

WARNING

If not installed, operated and maintained in 

accordance with the manufacturer’s instruc-

tions, this product could expose you to sub-

stances in fuel or from fuel combustion which 

can cause death or serious illness.

f i r e - p a r t s . c o m

Summary of Contents for MILLIVOLT 3 Series

Page 1: ...o light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas...

Page 2: ...ctronic System Operating Instructions 23 IPI Electronic System Wiring Diagram 24 Intermittent Pilot Lighting Instructions 25 Intermittent Control System Troubleshooting 26 28 Intermittent Pilot Propan...

Page 3: ...for use with glass doors or equivalent shall emphasize that the appliance is not for use with glass doors 11 Where applicable provide a means by which the consumer can identify the barrier such as gra...

Page 4: ...absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and...

Page 5: ...the person and company making the change WARNING ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS Improper installation or use of the fireplace can cause serious injury or death from fir...

Page 6: ...NS FIREPLACE DIMENSIONS BVD34FP BVD36FP BVP42FP Input Btu hr Maximum 21 000 25 000 30 000 KWH Maximum 6 2 7 3 8 8 B Vent Size 4 Diameter 6 Diameter 6 Diameter Natural Standard Orifice 44 086 P 252 42...

Page 7: ...ust be maintained from the perpendicular side wall and the screened opening of the appliance Figure 2 Combustible Material No greeting cards stockings or ornamentation of any type should be placed on...

Page 8: ...gas shut off should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for instal lation or relocation Compo...

Page 9: ...Gasvalveshaveabuilt inpressure regulator in the gas valve Natural Gas models will have a manifold pressure of approximately 3 5 w c 871kPa at the valve outlet with the inlet pressure to the valve from...

Page 10: ...ecommended that it be installed Installation of the fresh air kit should be performed at the framing stage of the fireplace installation The fresh air kit installs on the left side of the fireplace To...

Page 11: ...cover the black fireplace front WARNING When finishing the fireplace never obstruct or modify the air inlet outlet louvers in any manner Provide adequate clearances around air openings into the combus...

Page 12: ...draft ordown drafting Inthesecases increasing the vent height may solve this problem General Maintenance Conduct an inspection of the venting system semi annually Recommended areas to inspect are as f...

Page 13: ...around the vent system Do not pack air spaces with insulation or other material Vertical Venting No Elbows Figure 14 Offset Venting With Elbows Figure 15 Vent supports are per vent manufacturer s spec...

Page 14: ...he fireplace floor EMBER MATERIAL PLACEMENT ON BURNER 6 After all logs are positioned properly apply Rockwool ember material to the front burner port area To apply carefully separate the ember materia...

Page 15: ...when completing the following log placement steps 1 Place rear 1 log onto two 2 pins on rear log support 2 Place left front 2 log onto two 2 left front pins on burner pan 3 Place right front 3 log ont...

Page 16: ...1 minute time period you can release the gas control knob and the pilot will stay ON Allow your pilot flame to operate an additional one 1 to two 2 minutes before you turn the gas control knob from th...

Page 17: ...s After stripping and baring the wire ends connect the two stripped ends to the remote receiver Reconnect the 1 4 insulated wire terminal short 18 wire to the gas valve wire terminal See Figure 23 Mil...

Page 18: ...S VALVE PILOT VEILLEUSE MANUAL RESET LIMIT SWITCH WALL SWITCH INTERRUPTEUR MURAL THERMOPILE OPTIONAL REMOTE CONTROL RECEIVER FACULTATIVE CONTROLE E DISTANCE DU RECEPTEUR CONTROL RECEIVER CONTROLE E DI...

Page 19: ...1 STOP Read the safety information above 2 Set wall switch or remote to OFF 3 Turn off all electric power to the appliance if applicable 4 Open bottom louver assembly or open valve access door 5 Push...

Page 20: ...t Check the thermopile with a millivolt meter Take the reading at TH TP TP terminals of the gas valve The meter should read 350 millivolts minimum while holdingthevalveknobdepressedinthepilotposition...

Page 21: ...Fireplace BVD34FP3 SERIES BVD36FP3 SERIES BVP42FP3 SERIES Quantity Supplied Pilot Orifice 35 R 7658 35 R 7658 35 R 7658 1 Main Burner Orifice P 289 1 35mm P 208 1 45mm P 250 1 65mm 1 Dexen 10 w c Regu...

Page 22: ...n on the electrical supply to the appliance 24 Immediately test all gas line connections and the control valve for gas leaks using a soap and water solution or gas detection for solution Bubbles indic...

Page 23: ...r cord then plug the adapter into a 120V receptacle 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for Intermittent Pilot controls found in this manual and on labels found in the control compartment lo...

Page 24: ...e with other gases unless a certified kit is used CAUTION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified servi...

Page 25: ...es turn the gas shut off valve clockwise to OFF and call your service technician or gas supplier 12 Replace the front surround assembly or close bottom louver assembly if applicable 13 Operation of th...

Page 26: ...is present and that the batteries inside the receiver and or optional battery pack are fresh and installed with correct polarity Make sure all the connections between the wire harnesses and system com...

Page 27: ...ilot gas pressure incorrect Adjust gas pressure Pilot Gas Line bent or kinked Replace pilot tube Faulty pilot Sensor bent Replace Pilot Faulty valve Replace Valve Pilot continues to spark when pilot i...

Page 28: ...ing Move optional remote away from fireplace Set higher temperature on Optional remote ON OFF device Optional Remote control batteries failing Replace batteries in remote transmitter and receiver Faul...

Page 29: ...h the Intermittent Pilot fireplace Check the items in the kit with the parts list Notify the supplier of any items that are missing before installing the conversion kit intermittent pilot PROPANE GAS...

Page 30: ...below 19 Relight the main burners and verify proper burner ignition and operation 20 With the main burner burning read the pressure on the manometer or pressure gauge The pressure on the gauge should...

Page 31: ...Please Note It is normal for appliances fabricated of steel to give off someexpansionand orcontractionnoiseduringthestart up or cool down cycle Similar noises are found with your furnace heat exchange...

Page 32: ...2 ORIFICE NATURAL 19 R7572 R7572 R7572 R7572 JAMB NUT 20 P212 P212 P212 P212 ORIFICE HOLDER 21 19384 19384 38130 38130 TUBING ASSEMBLY 22 R2423 R2423 R2423 R2423 MALE ADAPTOR 23 N A N A 31300 31300 PI...

Page 33: ...10 11 12 13 14 16 24 19 17 18 26 27 28 21 20 15 29 30 35 36 37 38 39 22 40 41 Y MILLIVOLT BURNER ASSEMBLY 5 PIECE LOG ASSEMBLY 43 42 25 46 31 33 32 44 34 45 16 24 19 17 18 26 27 28 20 15 29 22 42 23 2...

Page 34: ...86 ORIFICE NATURAL 19 R7572 R7572 R7572 R7572 JAMB NUT 20 P212 P212 P212 P212 ORIFICE HOLDER 21 19420 19420 38131 38131 TUBING ASSEMBLY 22 R2423 R2423 R2423 R2423 MALE ADAPTOR 23 N A N A 31300 31300 P...

Page 35: ...5 4 2 3 1 8 9 9 10 11 12 13 14 16 24 19 17 18 26 27 28 21 20 15 29 30 35 36 37 38 39 22 40 41 Y MILLIVOLT BURNER ASSEMBLY 5 PIECE LOG ASSEMBLY 43 42 25 46 31 33 32 44 34 45 16 24 19 17 18 26 27 28 20...

Page 36: ...Y 21 R2423 R2423 R2423 R2423 MALE ADAPTOR 22 11377 11377 11377 11377 BURNER SUPPORT RIGHT SIDE 23 N A N A 31300 31300 PILOT BRACKET 24 R8132 R8132 R10423 R10423 PILOT NATURAL 25 R5710 R5710 N A N A TH...

Page 37: ...14 22 28 29 30 21 20 35 36 37 38 MILLIVOLT BURNER ASSEMBLY 4 PIECE LOG ASSEMBLY 16 19 17 18 27 15 26 24 41 42 25 40 39 8 8 9 9 10 11 45 31 33 32 43 34 44 24 25 29 21 42 23 20 IP BURNER 22 16 19 17 18...

Page 38: ...e back and push blower assembly against fireplace back The magnets on the back and bottom of blower assembly will sufficiently hold blower assembly in place 6 Position speed control box to the right o...

Page 39: ...N BOX WHITE SPEED CONTROL FAN SWITCH GROUND BLACK FAN 1 R7731 BLOWER AND MOTOR ASSEMBLY 2 R7649 FAN CONTROL 3 R4192 SPEED CONTROL KNOB 4 R4186 SPEED CONTROL Figure 26 Figure 27 FBB4 OPTIONAL VARIABLE...

Page 40: ...accordance with local codes or in the absence of local codes with the national electrical code ansi nfpa 70 latest edition A factory installed junction box is located on the lower right side of the fi...

Page 41: ...BVP3SA BVP42FP Fresh Air Kit Installs to side of fireplace to provide fresh air make up when operating fireplace optional Note Requires standard 4 diameter flexible or hard pipe connector not included...

Page 42: ...Arch Decorative Louver Leaf Decorative Frame Rectangle with hinges Decorative Door Plain Rectangle Bottom Trim Frame STD Louvers 45 Deg Outside Frame Kits Please contact your nearest dealer distribut...

Page 43: ...38142 2 0719 Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes fire parts com...

Page 44: ...38142 2 0719 Page 44 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes fire parts com...

Page 45: ...an be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number...

Page 46: ...32mm 1 1 4 32mm 1 1 4 32mm L 31 3 4 807mm 33 3 4 857mm 33 3 4 857mm M 32 11 16 830mm 34 11 16 881mm 34 11 16 881mm N 2 1 16 53mm 2 1 16 53mm 2 1 16 53mm O 5 5 8 143mm 5 5 8 143mm 5 5 8 143mm P 4 7 8 1...

Page 47: ...STIBLE TRIM AND MANTELS ALLOWED IN SHADED AREA 1 4 6 35mm 3 4 5 6 8 10 3 4 3 4 1 2 1 4 3 3 3 4 4 6 8 1 2 Clearance to Combustibles Back 0 0 mm Side 0 0 mm Floor 0 0 mm Top Stand off 0 0 mm Top Framing...

Page 48: ...any remote control thermostat lighting system accessory or replacement part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace it at Empire...

Reviews: