Proper Log Placement

Log placement is critical to proper burner performance. Logs must 

be correctly positioned. The photos in this manual show the proper 

position for logs in this set. Owners need to be shown proper log 

placement and instructed not to move the logs.

Proper Placement of Crushed Glass Media

This fireplace is designed to use crushed glass media on the burner. 

The maximum amount of crushed glass media should not exceed 

6 Sq. Ft. Spread out over the entire burner and burner screen. It is 

recommended that the crushed glass media be added after the log 

has been properly installed.

CAUtIoN

Do  not  place  crushed  glass  around  the  pilot  assembly. 

Crushed  glass  is  only  to  be  placed  on  the  burner  screen 

and burner cover. 

Make Owners Aware of Proper Log Set Operation

Properly  installed  and  properly  maintained  log  sets  should  not 

deposit soot on the logs. If users see excessive soot appearing 

on a log, call for service. Do not continue to operate the fireplace.

IMPortANt INStALLAtIoN gUIDeLINeS

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip

-

ment or accessories and repair and servicing of equipment shall be 

performed only by a qualified agency. The term "qualified agency" 

means any individual, firm, corporation, or company that either in 

person or through a representative is engaged in and is responsible 

for (a) the installation, testing, or replacement of gas piping or (b) the 

connection, installation, testing, repair, or servicing of equipment; 

that is experienced in such work; that is familiar with all precautions 

required, and that has complied with all the requirements of the 

authority having jurisdiction.
The installation must conform with local codes or, in the absence of 

local codes, with the 

National Fuel Gas Code, ANSI Z223.1/NFPA54

.*

*Available from the American National Standards Institute, Inc. 11 

West 42nd St., New York, N.Y. 10018.

geNerAL INforMAtIoN

Commonwealth of Massachusetts: 

The installation must be 

made by a licensed plumber or gas fitter in the Commonwealth 

of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental 

room heaters shall provide to each purchaser a copy of 527 CMR 

30 upon sale of the unit.

Appliance Certification

This logset is design certified in accordance with American National 

Standard/CSA Standard ANSI Z21.88/CSA 2.33 and by Underwrit

-

ers Laboratories for use with a Direct Vent Gas Fireplace Heater 

and shall be installed according to these instructions.

Summary of Contents for LS55CD-1

Page 1: ...ghbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency o...

Page 2: ...NTS Important Installation Guidelines 3 General Information 3 Log Identification 4 5 Log Placement 6 16 Completing Installation 17 Master Parts Distributor List 18 How To Order Repair Parts 18 Firepla...

Page 3: ...repair and servicing of equipment shall be performed only by a qualified agency The term qualified agency means any individual firm corporation or company that either in person or through a representa...

Page 4: ...41485 0 0120 Page 4 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12928 Log A R12929 Log B R12930 Log C R12931 Log D R12932 Log E LOG IDENTIFICATION...

Page 5: ...41485 0 0120 Page 5 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12933 Log F R12934 Log G R12935 Log H R12936 Log I LOG IDENTIFICATION...

Page 6: ...r failure to use only parts specifically approved with this appliance may result in property damage or personal injury Attention Refer to Pages 4 and 5 Parts List and Parts View to order logs or rocks...

Page 7: ...41485 0 0120 Page 7 LOG PLACEMENT 1 Place Log A onto burner pin as shown TOP VIEW FRONT VIEW...

Page 8: ...41485 0 0120 Page 8 LOG PLACEMENT 2 Place Log B onto burner as shown TOP VIEW FRONT VIEW...

Page 9: ...41485 0 0120 Page 9 LOG PLACEMENT 3 Place Log C onto burner as shown TOP VIEW FRONT VIEW...

Page 10: ...41485 0 0120 Page 10 LOG PLACEMENT 4 Place Log D onto burner and Log C as shown TOP VIEW FRONT VIEW...

Page 11: ...41485 0 0120 Page 11 LOG PLACEMENT 5 Place Log E onto burner as shown TOP VIEW FRONT VIEW...

Page 12: ...41485 0 0120 Page 12 LOG PLACEMENT 6 Place Log F onto burner as shown TOP VIEW FRONT VIEW...

Page 13: ...41485 0 0120 Page 13 LOG PLACEMENT 7 Place Log G onto Log B Log G will rest on the burner and touch Logs A and D as shown TOP VIEW FRONT VIEW...

Page 14: ...41485 0 0120 Page 14 LOG PLACEMENT 8 Place Log H on top of Logs C and E as shown Log H will not touch the burner TOP VIEW FRONT VIEW...

Page 15: ...41485 0 0120 Page 15 LOG PLACEMENT 9 Place Log I on the burner and into the groove of Log F as shown TOP VIEW FRONT VIEW...

Page 16: ...place installation instruction manual If excessive flame impingement occurs on any of the cross Logs D G and H these logs can be rotated left right away from the flame to improve performance In additi...

Page 17: ...ace embers covering all burner ports as shown in the area below 2 Mix remaining decorative media together as desired and spread across burner screen Also fill area between the two pieces of glass Fina...

Page 18: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Page 19: ...41485 0 0120 Page 19 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 20: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Reviews: