background image

41097-0-0120

Page 4

REQUIREMENTS FOR CANADA

This unit 

cannot

 be installed in a UNVENTED application, 

this  unit

 can only 

be  installed  as  a  VENTED  application 

with these requirements.

IMPORTANT SAFETY INFORMATION

This unit complies with ANSI Z21.60and CGA 2.26 Decora-

tive Gas Appliances For Installation In Solid Fuel Burning 

Fireplaces. Do not burn wood or solid fuels in a fireplace 

where a decorative gas log set is installed. This appliance is 

for installation only in a solid fuel burning fireplace, masonry 

fireplace or manufactured fireplace.

WARNING: 

Any modification to this gas log set can be dan-

gerous. Improper installation or use of the gas log set can 

cause serious injury or death from fire, burns, explosion or 

carbon monoxide poisoning.
1.  Please  follow  all  local  codes  regarding  installation, 

combustion  and  ventilation  air  or  in  the  absence  of 

local  codes  follow  the  National  Fuel  Gas  Code ANSI 

Z223.1(U.S.  installation),  or  CAN/CGA-B149,  Installa-

tion Code (Canada installation).

2.  Proper installation, burner location and log placement 

is important to achieve optimum look and performance 

of your gas log set. The logs have been designed for 

easy location and placement on the grate and must be 

followed for proper operation.

3.  Do not operate the burner with glass doors in the closed 

position. A fireplace screen must be in place when the 

burner  is  burning.  Adequate  combustion  air  must  be 

provided for proper venting. All flames should go up and 

out the top of the firebox into the flue vent. If any flames 

float or curl forward into the room do not operate appli-

ance. Check for an open flue and adequate combustion 

air into the room. A damper clamp must be installed on 

the firebox damper to maintain an open flue vent condi-

tion.    Refer  to  fireplace  owners  manual  INSTALLING 

DAMPER CLAMP section.

4.  Young children must be carefully supervised when they 

are in the same room as an operating vent-free burner. 

Do not place stockings, clothing or any flammable ma-

terial above or near the fireplace.

5.  Do not substitute or use materials other than those sup-

plied for use with the log set.

6.  Also refer to IMPORTANT SAFETY INFORMATION in 

the fireplace Owner's Manual.

WARNING;  DO  NOT  OPERATE  THIS  GAS  LOG  SET 

WITH GLASS DOORS CLOSED

•  Clothing  or  other  flammable  material  should  not  be 

placed on or near the appliance.

•  Do not place debris or other articles on the log set dur-

ing operation.

•  A window should be opened during the initial bake out 

period.

•  Installation  and  repair  should  be  done  by  a  qualified 

service  person.  The  appliance  should  be  inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, etc. It 

is  imperative  that  control  compartments,  burners  and 

circulating  air  passageways  of  the  appliance  be  kept 

clean.

• 

Do not

 use this appliance if any part has been under 

water.  Immediately  call  a  qualified  service  technician 

to inspect the appliance and to replace any part of the 

control system and any gas control which has been un-

der water. 

•  Never burn solid fuels in fireplace where a gas log set is 

installed.

•  This unit complies with ANSI Z21.60 Decorative Vented 

Appliances for Solid Fuel Burning Fireplaces. State or 

local codes may only allow operation of this appliance 

in  a  vented  configuration.  Check  your  state  or  local 

codes.

Summary of Contents for LS18CB-1

Page 1: ... call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Log sets comply with ANSI Z21 11 2 Unvented Heaters and also comply with ANSI Z21 60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces State or local codes may on...

Page 2: ...rements for Canada 4 LS 18 24 30 CB Log Sets 5 Log Identification LS18CB 6 Log Placement LS18CB 7 14 Log Identification LS24CB 15 Log Identification LS30CB 16 Log Placement LS 24 30 CB 17 24 Ember Placement LS 18 24 30 CB 25 Appliance Service History 26 Master Parts Distributor List 27 How To Order Repair Parts 27 ...

Page 3: ...ation Properly installed and properly maintained log sets do not deposit soot on the logs If users see soot on a log they should call for service Do not continue to operate the log set Sunken Fireplace If installing this unit into a sunken fireplace raise the floor to ensure adequate airflow and guard against sooting Raise fireplace floor using a non combustible material which is secure Glass Door...

Page 4: ...ce Check for an open flue and adequate combustion air into the room A damper clamp must be installed on the firebox damper to maintain an open flue vent condi tion Refer to fireplace owners manual INSTALLING DAMPER CLAMP section 4 Young children must be carefully supervised when they are in the same room as an operating vent free burner Do not place stockings clothing or any flammable ma terial ab...

Page 5: ...41097 0 0120 Page 5 LS 18 24 30 CB LOG SETS LS24CB LOG SET LS30CB LOG SET LS18CB LOG SET ...

Page 6: ... 6 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12811 Rear Left Log A R12812 Rear Right Log B R12813 Rear Right Log C R12814 Front Left Log D R12815 Left Branch Log E R12816 Right Branch Log F LOG IDENTIFICATION LS18CB ...

Page 7: ...nvented gas burner assembly WARNING This appliance is equipped for natural or propane gas Field conversion is not permitted Apply glowing embers per the ember placement section of this manual on page 30 Replace glowing embers with appropriate part number from the table below from Empire Comfort Systems Inc Application of excess glowing embers may adversely affect perfor mance of the heater WARNING...

Page 8: ...41097 0 0120 Page 8 1 Place Log A onto left rear pin on rear log support LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 9: ...41097 0 0120 Page 9 2 Place Log B onto two 2 right front pins on burner pan LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 10: ...41097 0 0120 Page 10 3 Place Log C onto right rear pin on rear log support LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 11: ...41097 0 0120 Page 11 4 Place Log D onto two 2 left front pins on burner pan LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 12: ...41097 0 0120 Page 12 5 Place Log E on top of the pin located on Log A Log E should rest on top of the left side of Log D LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 13: ...41097 0 0120 Page 13 6 Place Log F on top of the pin located on Log C Log F should rest on top of the left side of Log B and the right side of Log D LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 14: ...41097 0 0120 Page 14 7 Log placement is complete LOG PLACEMENT LS18CB CONT D TOP VIEW FRONT VIEW ...

Page 15: ...15 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12817 Rear Left Log A R12818 Front Right Log B R12819 Rear Right Log C R12820 Front Left Log D R12821 Left Branch Log E R12822 Right Branch Log F LOG IDENTIFICATION LS24CB ...

Page 16: ...16 PART NUMBER DESCRIPTION TOP VIEW FRONT VIEW R12823 Rear Left Log A R12824 Front Right Log B R12825 Rear Right Log C R12826 Front Left Log D R12827 Left Branch Log E R12828 Right Branch Log F LOG IDENTIFICATION LS30CB ...

Page 17: ... set is installed onto an unvented gas burner assembly WARNING This appliance is equipped for natural or propane gas Field conversion is not permitted Apply glowing embers per the ember placement section of this manual on page 30 Replace glowing embers with appropriate part number from the table below from Empire Comfort Systems Inc Application of excess glowing embers may adversely affect perfor ...

Page 18: ...41097 0 0120 Page 18 LOG PLACEMENT LS 24 30 CB CONT D 1 Place Log A onto left rear pin on rear log support FRONT VIEW TOP VIEW ...

Page 19: ...41097 0 0120 Page 19 FRONT VIEW TOP VIEW LOG PLACEMENT LS 24 30 CB CONT D 2 Place Log B onto two 2 right front pins on burner pan ...

Page 20: ...41097 0 0120 Page 20 LOG PLACEMENT LS 24 30 CB CONT D 3 Place Log C onto right rear pin on rear log support FRONT VIEW TOP VIEW ...

Page 21: ...41097 0 0120 Page 21 LOG PLACEMENT LS 24 30 CB CONT D 4 Place Log D onto two 2 left front pins on burner pan FRONT VIEW TOP VIEW ...

Page 22: ...41097 0 0120 Page 22 LOG PLACEMENT LS 24 30 CB CONT D 5 Place Log E on top of the pin located on Log A Log E should rest on top of the left side of Log D FRONT VIEW TOP VIEW ...

Page 23: ...97 0 0120 Page 23 LOG PLACEMENT LS 24 30 CB CONT D 6 Place Log F on top of the white pin located on Log C Log F should rest on top of the left side of Log B and the right side of Log D FRONT VIEW TOP VIEW ...

Page 24: ...41097 0 0120 Page 24 LOG PLACEMENT LS 24 30 CB CONT D 7 Log placement is complete FRONT VIEW TOP VIEW ...

Page 25: ...41097 0 0120 Page 25 EMBER PLACEMENT LS 18 24 30 cb Do not cover any large rear ports with glowing embers Do not cover any large front ports with glowing embers Area for glowing embers ...

Page 26: ...41097 0 0120 Page 26 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Page 27: ...ase and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be ...

Page 28: ...www empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer ...

Reviews: