background image

37001-5-0220

Page 1

Empire Comfort Systems Inc. • Belleville, IL

AUTO VARIABLE-SPEED-TWIN

FOR USE ON: DVCT(36,40,50) SERIES FIREPLACES

INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION.

CAUTION

Sharp edges. Use protective gloves when installing.

BENCH INSTALLATION

1.  Remove Blower Access Panels.

 See Figure 1.

Figure 1

2.  Place Blower onto blower brackets. 

See Figure 2.

Figure 2

3.  Hand bend tab as shown in

 Figure 3 

and secure with 

 

(2) screws.

HAND BEND

TAB INWARD

HAND BEND

TAB INWARD

Figure 3

4.  Remove protective connectors on Wire Assembly from 

fireplace and discard. Connect Wire Harness to both blowers 

and the other end to the Wire Assembly supplied with the 

fireplace.

 

See Figure 4.

TO WIRE ASSEMBLY

(MODULE)

Figure 4

5.  Replace Blower Access Panels removed in step 1. 

 

See Figure 1.

INSTALLATION AFTER PLACEMENT OF UNIT IN WALL

1.  Remove the following items: 

See Figure 5.

• 

 Screen  barrier 

(see Homeowner’s Manual, Maintenance 

and Service).

• 

 Glass  Frame  Assembly 

(see Homeowner’s Manual, 

Maintenance and Service).

• 

Liners 

(see separate liner instruction document).

Figure 5

2.   Remove front and rear burner. 

See

 

Figure 6.

 

Figure 6

DVCT40 SHOWN

DVCT40 SHOWN

DVCT40 SHOWN

DVCT40 SHOWN

INSTALLATION INSTRUCTIONS

FBB21 BLOWER

Reviews: