26927-8-0611
Page 8
FRONT FACE (SIDE)
FIREPLACE
(TOP VIEW)
3
MAX.
PERPENDICULAR
SIDE WALL
45°
6
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
Figure 4
Clearances (Figure 5)
Clearance from top of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
36”
(914mm)
6” (152mm)
Figure 5
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
NOTICE
:
Empire "Standard Mantels" are not approved for use with
the DVP36DP(31,71,91)(N,P) Series fireplaces.
Mantel Chart (Figure 3)
Figure 3
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
NON-COMBUSTIBLE
FIRST 3 (SEE MAGNIFFIED
VIEW)
”
NAILING
FLANGES
GLASS FRONT
TOP FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
3"
CLEARANCES