Flush Wall Installation
Figure 13
Combustible Surround Installation
Figure 14
Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated
exterior wall, it is recommended that the outer walls be
insulated to conform to applicable insulation codes.
vent Runs (Figures 15, 16, 17, 18 and 19)
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact
all four (4) perimeter edges on the bottom of the unit.
NOTICE
: Fireplace must be mounted above floor surfaces. Doors
will not operate properly if fireplace rests below room flooring.
vERTICAL, 90° ELBOW WITH HORIzONTAL TERMINATION
Figure 15
Lp and Nat models
FINISHED WALL
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
3” OF NON-COMBUSTIBLE MATERIAL
NONCOMBUSTIBLE MATERIAL
(INSTALLATION IS OPTIONAL)