The Heritage Cast Iron Stoves
Models:
DVP20CC(30,70)(B,F,M)(N,P)-1
DVP30CC(30,70)(B,F,M,S,W)(N,P)-1
CLEARANCES
In selecting a location for installation, it is necessary to provide adequate accessibility
clearances for servicing and proper operation.
Locating and Venting the Direct Vent Stove
Clearances: When facing the front of the direct vent stove the minimum clearances
to combustible construction (material) are the following:
Top of appliance (ceiling)
36 (inches)
Heater Corners
(45° angle) to Wall
4 (inches)
Rear Wall
1 (inches)
Floor
0 (inches)
Side Wall
6 (inches)
Installation on Rugs and Tile
This appliance must be installed on a
flat, solid, continuous surface (e.g. wood,
metal, concrete). This may be the floor,
or it may be raised up on a platform to
enhance its visual impact. The appliance
may be installed on carpeting, tile, wood
flooring or other combustible material as
the appliance's base extends the width
and depth of the appliance.