29004-0-0711
Page 10
6 1/4”
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
FIRST 6 1/4” (SEE
MAGNIFIED VIEW)
TOP FRAMING
LEDGE
GLASS FRONT
2 X 4 HEADER
STANDOFF 3” (76mm) HEIGHT
ABOVE TOP OF FIREPLACE
NAILING
FLANGES
Figure
2
6 1/2”
MINIMUM CLEARANCE TO PERPENDICULAR
COMBUSTIBLE SIDE WALLS
(FROM EDGE OF FIREPLACE DOOR FRAME)
Figure
3
Clearance to Combustibles
Air Drop (End)
1/2" (12.7 mm)
Side
1/2" (12.7 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
6 1/4" (159 mm)
CLEARANCES
Figure
4a - See Through Fireplace Clearances
Figure
4b - Fireplace Clearances
36”
MIN.
32”
MIN.
(CEILING TO
TOP OF DOOR)
61/2” MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
COMBUSTIBLE
FRAMING ALLOWED
6 1/4" MIN. CLEARANCE
TO COMBUSTIBLES
REQUIRED
NON-COMBUSTIBLE
FINISHING MATERIALS
ONLY
NAILING FLANGE
(SECURE UNIT WITH
NAILING FLANGE)
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.