Page 2

R-3451

Introduction
Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of an unvented room
heater.

This appliance may be installed in an aftermarket* permanently located,
manufactured (mobile) home, where not prohibited by state or local
codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the

manufacturer.

This appliance is only for use with the type of gas indicated on the rating
plate.

Instructions to Installer
1.

Installer must leave instruction manual with owner after installa-
tion.

2.

Installer must have owner fill out and mail warranty card supplied
with unvented room heater.

3.

Installer should show owner how to start and operate unvented
room heater.

WARNING: ANY CHANGE TO THIS HEATER OR ITS CON-
TROLS CAN BE DANGEROUS.

Any safety screen or guard removed for servicing an appliance
must be replaced prior to operating the heater.

WARNING

More frequent cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is imperative that
control compartments, burners and circulating air passageways
of the appliance be kept clean.

DO make a periodic visual check of pilot and burners. Clean and
replace damaged parts.

DO NOT use this room heater if any part has been under water.
Immediately call a qualified service technician to inspect the
room heater and to replace any part of the control system and
any gas control which has been under water.

Due to high surface temperatures, keep children, clothing and
furniture away.

Under no circumstances should any solid fuels (wood, coal, paper
or cardboard etc.) be used in this appliance.

The flow of combustion and ventilation air must not be obstructed
in any way.

An unvented room heater having an input rating of more than
10,000 Btu per hour shall not be installed in a bedroom or
bathroom.

Due to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazard of high
surface temperature and should stay away to avoid burns or
clothing ignition.

Young children should be carefully supervised when they are
in the same room with the appliance.

Do not place clothing or other flammable material on or near
the appliance.

Keep burner and control compartment clean.

Installation and repair should be done by a QUALIFIED
SERVICE PERSON. The appliance should be inspected before
use and at least annually by a professional service person.

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

When used without adequate combustion and ventilation air,
heater may give off CARBON MONOXIDE, an odorless, poison-
ous gas.

Do not install heater until all necessary provisions are made
for combustion and ventilation air. Consult the written in-
structions provided with the heater for information concern-
ing combustion and ventilation air. In the absence of instruc-
tions, refer to the National Fuel Gas Code, ANSI Z223.1,
Section 5.3 or applicable local codes.

This heater is equipped with a PILOT LIGHT SAFETY SYS-
TEM designed to turn off the heater if not enough fresh air is
available.

DO NOT TAMPER WITH PILOT LIGHT SAFETY
SYSTEM!

If heater shuts off, do not relight until you provide fresh air.

If heater keeps shutting off, have it serviced. Keep burner and
control compartment clean.

CARBON MONOXIDE POISONING MAY LEAD TO
DEATH.

Early signs of carbon monoxide poisoning resemble the flu, with
headache, dizziness and/or nausea. If you have these signs, heater
may not be working properly. Get fresh air at once! Have heater
serviced.

Some people — pregnant women, persons with heart or lung
disease, anemia, those under the influence of alcohol , those at high
altitudes — are more affected by carbon monoxide than others.

The pilot light safety system senses the depletion of oxygen at its
location. If this heater is installed in a structure having a high
vertical dimension, the possibility exists that the oxygen supply at
the higher levels will be less than that at the heater. In this type of
application, a fan to circulate the structure air will minimize this
effect. The use of this fan will also improve the comfort level in the
structure. When a fan is used to circulate air, it should be located
so that the air flow is not directed at the burner.

General Information
This CIVF-25 is design certified in accordance with American National
Standards Institute Z21.11.2b-1998 by the American Gas Associaton as
an Unvented Room Heater and should be installed according to these
instructions.

Attention: During initial use of ceramic log you will detect an odor
as the ceramic log is cured. Also, during the curing process the
ceramic log will burn with a yellow flame.

Any alteration of the original design, installed other than as shown
in these instructions or use with a type of gas not shown on the rating
plate is the responsibility of the person and company making the
change.

Important
All correspondence should refer to complete Model No., Serial No. and
type of gas.

Notice: During initial firing of this unit, its paint will bake out, and
smoke will occur. To prevent triggering of smoke alarms, ventilate the
room in which the unit is installed.

Summary of Contents for CIVF-25-2

Page 1: ...om bustion An unvented room heater pro duces approximately one 1 ounce 30ml ofwaterforevery1 000BTU s 3KW s of gas input per hour Refer to page 4 FORYOUR SAFETY What to do if you smell gas Do not touch any electrical switches Do not try to light any appliance Donotusethephoneinyourbuilding Immediately call your gas supplier from a neighbor s phone Followthegassupplier sinstructions Ifyoucannotreac...

Page 2: ...ANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED When used without adequate combustion and ventilation air heater may give off CARBON MONOXIDE an odorless poison ous gas Do not install heater until all necessary provisions are made for combustion and ventilation air Consult the written in structions provided with the heater for information concern ing combustion and ventilation air...

Page 3: ...orm service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old ta...

Page 4: ...liancethefollowingminimumclearances to combustible construction must be maintained Top of appliance ceiling 24 inches Rear Wall 2 inches Side Wall 6 inches Heater Corners 45 angle to Wall 4 inches Floor 0 inches Provide adequate clearances around air openings Adequate accessibility clearances for purposes of servicing and proper operation must be provided Installation on Rugs and Vinyl If this app...

Page 5: ...Page 5 R 3451 Figure 1 Figure 2 Figure 3 ...

Page 6: ...sing side Attach the two rear leg pads to the casing sides with 2 3 8 bolts Attach but do not completely tighten the two front leg pads to the casing sides with 2 3 8 bolts Attention The front leg pads can be adjusted to provide a snug fit between the casing front and the casing sides 4 Attach 4 leveling bolts to the bottom of the 4 legs 5 Align the 3 8 hole at the top of the leg with the 3 8 hole...

Page 7: ... push inward on the leg in order to provide a snug fit between the casing front and the casing side Continue to hold the right front leg as you completely tighten the 2 3 8 bolts that attach the leg pad to the right casing side Repeatprocedureforleft frontlegtoachieveasnugfitbetween the casing front and the casing side 13 Remove the casing front from the outer casing 14 Refer to Figure 9 the appli...

Page 8: ...e standard grille top is replaced with a stone inlay you must install the top shield and heat shield which are provided with the stone inlay Installation of Optional Stone Inlay 1 Remove left grille center grille and right grille from casing top 2 Remove casing top from outer casing Figure 7 ...

Page 9: ...0 1 2 1 2 5 8 1 2 1 3 cm 1 3 cm 1 6 cm 1 3 cm 40 100 1 2 1 2 3 4 1 2 1 3 cm 1 3 cm 1 9 cm 1 3 cm 100 150 3 4 1 2 7 8 3 4 1 9 cm 1 3 cm 2 2 cm 1 9 cm Note Never use plastic pipe Check to confirm whether your local codes allow copper tubing or galvanized Note Since some municipalities have additional local codes it is always best to consult your local authority and installation code Installing a New...

Page 10: ...m of the gas appliance pressure regulator for measuring gas pressure The connection is a 1 8 inch 3mm N P T plugged tapping High Altitudes For altitudes elevations above 2 000 feet 610m ratings should be reduced at the rate of 4 percent for each 1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size Keep appliance area clear and free from com...

Page 11: ...hat can be purchased for use with your log set Operation of ON OFF REMOTE Switch with no Accessories To ignite main burner turn the control knob on the gas valve from the PILOT position to the ON position Turn the ON OFF REMOTE switch from the OFF position to the ON position The additional green wire and red wire which are stripped and bare are not used Operation of ON OFF REMOTE Switch with Acces...

Page 12: ...ill be to the bottom on the slide on cover plate 2 Push the receiver slide button onto the receiver slide switch Reverse installation of the slide button if it is off center 3 Attach velcro loop on the left side of the valve cover support 4 Attach velcro hook onto remote receiver The word TOP on the remote receiver should be to the top when installed onto valve cover support 5 Attach velcro hook o...

Page 13: ...ol valve knob in the ON position This will allow the pilot flame to remain lit Turn the burner flame on or off with the appliance ON OFF rocker switch wall switch remote control kits or 750 millivolt wall thermostat NOTE The gas control valve allows you to increase or decrease the height of the main burner flame The control valve has a pressure regulator with a knob as shown in Figure 20 Rotate th...

Page 14: ...Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance if appli cable 4 Lower valve cover 5 Push in gas control knob slightly and turn clockwise to OFF 6 Wait ten 10 minutes to clear out any gas Then smell forgas includingnearthefloor Ifyousmellgas STOP Follow B inthesafetyinformationabove Ifyoudon t smell gas go to the next step 7 F...

Page 15: ...ire connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading at TH TP TP terminals of the gas valve The meter should read 350 millivolts minimum while holding the valve knob depressed in the PILOT position with the pilot lit and the ON OFF switch in the OFF position ...

Page 16: ...e a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Heater Model Number Part Description Heater Serial Number Kind of Gas Propane or Natural Part Number Do not order bolts s...

Page 17: ... 4 REQUIRED BLACK PAINT 13 R 3742 LEG 4 REQUIRED BLACK ENAMEL 13 R 3743 LEG 4 REQUIRED SAND ENAMEL 13 R 3744 LEG 4 REQUIRED GREEN ENAMEL 13 R 3745 LEG 4 REQUIRED RED ENAMEL 13 R 3746 LEG 4 REQUIRED NAVY ENAMEL 14 R 3945 SIDE LEFT BLACK PAINT 14 R 3684 SIDE LEFT BLACK ENAMEL 14 R 3692 SIDE LEFT SAND ENAMEL 14 R 3700 SIDE LEFT GREEN ENAMEL 14 R 3708 SIDE LEFT RED ENAMEL 14 R 3716 SIDE LEFT NAVY ENAM...

Page 18: ...Page 18 R 3451 ...

Page 19: ...left side of the rear cover 15 Attach wire channel to rear cover by using 4 hex head screws removed in Step 4 Refer to Installation of Wire Channel Assembly Page 9 16 Insert AUTO OFF ON switch into rectangular notch on valve bracket Be sure to insert AUTO OFF ON switch with letters words upright See wiring diagram 17 Attach 1 4 push on terminal from blue wire on the fan control to the AUTO top tab...

Page 20: ... No No Description 1 R 1454 Brass Bushing 4 Required 2 R 1499 Rubber Grommet 4 Required 3 CI 002 Blower Housing 4 R 1517 Tinnerman Clip 4 Required 5 R 2804 A Blower Assembly 6 CI 003 Blower Housing Cover 7 R 2099 Cord Set 8 R 3767 A Wire Harness 9A CI 004 Fan Control Bracket Use with CIBV 30 CIVF 25 CIVF 25C Only 9B CI 325 Fan Control Bracket Use with CIDV 30 Only 10 R 2503 Fan Control 11 R 2805 A...

Reviews: