background image

R-3450

Page 1

FOR YOUR SAFETY: What to do if you
smell gas:

Do not touch any electrical switches

Do not try to light any appliance.

Do not use the phone in your building.

Immediately call your gas supplier
from a neighbor's phone.

Follow the gas supplier's instructions.

If you cannot reach your gas supplier,
call the fire department.

INSTALLATION INSTRUCTIONS

AND

OWNER'S MANUAL

CAST IRON

VENTED FIREPLACE HEATER

MODEL

CIBV-30-2

    

EFFECTIVE  DATE

APRIL, 2000

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier. Do not store
or use gasoline or other flammable va-
pors and liquids in the vicinity of this or
any other appliance.

AVERTISSEMENT: Quiconque ne respecte
pas à la lettre les instructions dans le présent
manuel risque de déclencher un incendie ou
une explosion entraíant des dommages
matériels, des lésions corporelles ou la perte de
vies humaines. Installation ou modification,
consulter le manuel des usagers fourn avec ce
générateur d'air chaud. Ne pas entreposer ni
utiliser d'essence ni d'autres  vapeurs ou liquides
inflammables dans le voisinage de cet appareil
ou de tour autre appareil.

POUR VOTRE SÉCURITÉ: Que faire si vous
sentez une odeur de gaz:

Ne pas tenter d'allumer d'appareil.

Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez.

Évacuez la pièce, le bâtiment ou la zone.

Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les
instructions du fournisseur.

Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service dos incendies.

Summary of Contents for CIBV-30-2

Page 1: ...ds in the vicinity of this or any other appliance AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans le présent manuel risque de déclencher un incendie ou une explosion entraíant des dommages matériels des lésions corporelles ou la perte de vies humaines Installation ou modification consulter le manuel des usagers fourn avec ce générateur d air chaud Ne pas entreposer ni uti...

Page 2: ...icing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control compartment clean Installation and repair should be done by a QUALIFIED SER VICEPERSON Thefireplaceheatershouldbeinspectedbefore use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpe...

Page 3: ...orm service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old ta...

Page 4: ...diction The installation must conform with local codes or in the absence of local codes the current National Fuel Gas Code ANSI Z223 1 NFPA 54 or CAN1 B149 Gas Appliance Installation Code Installer l appareil selon les codes ou règlements locaux ou en l absence de tels règlements selon les Codes d installation CAN CGA B149 Available from the American National Standards Institute Inc 11 West 42nd S...

Page 5: ... do not completely tighten the two front leg pads to the casing sides with 2 3 8 bolts Attention The front leg pads can be adjusted to provide a snug fit between the casing front and the casing sides 4 Attach 4 leveling bolts to the bottom of the 4 legs 5 Align the 3 8 hole at the top of the leg with the 3 8 hole in the leg pad Attention For proper positioning of the leg to the leg pad the 2 1 1 2...

Page 6: ...aining tabs should be positioned downward from the casing front top to the casing front bottom 11 Refer to Figure 8 attach casing front to outer casing by using the 4 retaining tabs on the casing front The 2 top retaining tabs on the casing front will be placed behind the 2 top locator tabs on the front of the casing sides The 2 bottom retaining tabs will be inserted into the 2 9 16 slots on the f...

Page 7: ...ecure the valve cover in place during shipping The 1 Phillips head screw can be discarded 15 Attach casing front to outer casing as described in Step 11 16 Place the casing top onto the outer casing The casing top nests into the outer casing 17 Insert center grille left grille and right grille into casing top 18 Level appliance by adjusting leveling bolts 19 Assembly of cast iron outer casing stov...

Page 8: ...2 metal clips on exterior of rear cover Attach 2 1 4 female push ons on vent safety switch wire harness onto 2 1 4 male tabs on vent safety switch which is located on the side of draft diverter Figure 10 Venting 1 Flue pipe must be as large as the flue collar on the draft diverter 2 Maintain an upward slope of at least 1 4 inch 6mm per foot of horizontal run 3 Run flue pipe as directly as possible...

Page 9: ...ipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect Method of Installing A Tee Fitting Sediment Trap Figure 11 Pressure Testing of the Gas Supply System 1 To check the inlet pressure to the gas valve a 1 8 3mm N P T plugged tapping accessible for the test gauge connection must be placed immediately upstream of the gas supply conn...

Page 10: ... an altitude of Orifice size Manifold Pressure Input Btu h Fuel Type Date of Conversion Converted by Cet appareil a été converti au Injecteur Pression à la tubulure d alimentation Déoit calorifique Piezo Ignitor Button The piezo ignitor button is located behind the valve cover Depressing the button causes a spark to occur at the pilot On a new installation with air in the gas line depress the piez...

Page 11: ...he wiring chase A wire harness is attached to the ON OFF REMOTE switch The red black and green wires female push ons attach to the ON OFF REMOTE switch At the opposite end of the wire harness the black and green wires female push ons attach to the gas valve An additional green wire and the red wire which are stripped and bare will attach to the 750 millivolt wall thermostat accessory or to one of ...

Page 12: ...manual mode You must turn the appliance ON or OFF with appropriate accessory Wall Thermostat Operation 1 Turn the ON OFF REMOTE switch on wiring chase to REMOTE position 2 Turn accessory FRBC 1 FREC 1 or FWS 1 OFF 3 Turn wall thermostat ON and set appropriate temperature Wall thermostat will cycle the appliance ON and OFF Installation of Remote Receiver Figure 17 1 Attach from left to right the sl...

Page 13: ...ront log onto the two front pins on the base 7 Align the two alignment holes on the underside of the top log with the alignment pins on the top of front log Place the top log onto the two pins on the front log 8 Grasp bottom of glass frame push upward and insert glass frame into glass frame support top push inward and insert glass frame into glass frame guide 9 Attach two door latches to bottom of...

Page 14: ...burner flame on or off with the appliance ON OFF rocker switch wall switch remote control kits or 750 millivolt wall thermostat NOTE The gas control valve allows you to increase or decrease the heightofthemainburnerflame Thecontrolvalvehasapressureregulator with a knob as shown in Figure 21 Rotate the knob clockwise to HI to increase the flame height and counterclockwise to LO to decrease the flam...

Page 15: ... off all electric power to appliance if service is to be performed if applicable 3 Lower valve cover 4 Push in gas control knob slightly and turn clock wise to OFF Do not force 5 Raise valve cover TO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance if appli cable 4 Lower va...

Page 16: ...ective Check on off switch and wires for proper connections Place jumper wires across terminal at switch if burner comes on replace defective switch If OK place jumper wires across switch wires at gas valve if burner comes on wires are faulty or connections are bad b Thermopile may not be generating sufficient milli voltage Ifthepilotflameisnotcloseenoughphysicallytothethermopile adjust the pilot ...

Page 17: ...R 3450 Page 17 ...

Page 18: ...NAMEL 2 R 3712 WINDOW RED ENAMEL 2 R 3720 WINDOW NAVY ENAMEL 3 R 3949 GRILL LEFT BLACK PAINT 3 R 3726 GRILL LEFT BLACK ENAMEL 3 R 3729 GRILL LEFT SAND ENAMEL 3 R 3732 GRILL LEFT GREEN ENAMEL 3 R 3735 GRILL LEFT RED ENAMEL 3 R 3738 GRILL LEFT NAVY ENAMEL 4 R 3950 GRILL CENTER BLACK PAINT 4 R 3727 GRILL CENTER BLACK ENAMEL 4 R 3730 GRILL CENTER SAND ENAMEL 4 R 3733 GRILL CENTER GREEN ENAMEL 4 R 3736...

Page 19: ...R 3450 Page 19 ...

Page 20: ...from blue wire on the fan control to the AUTO top tab on the switch 12 Attach 1 4 push on terminal from black wire to the OFF middle tab on the switch 13 Attach 1 4 push on terminal from white wire on the fan control to the ON bottom tab on the switch 14 Installation of optional CIB 2 blower is completed Fan Control The fan control is a non adjustable automatic type The fan control will require be...

Page 21: ...t No No Description 1 R 1454 Brass Bushing 4 Required 2 R 1499 Rubber Grommet 4 Required 3 CI 002 Blower Housing 4 R 1517 Tinnerman Clip 4 Required 5 R 2804 A Blower Assembly 6 CI 003 Blower Housing Cover 7 R 2099 Cord Set 8 R 3767 A Wire Harness 9A CI 004 Fan Control Bracket Use with CIBV 30 CIVF 25 CIVF 25C Only 9B CI 325 Fan Control Bracket Use with CIDV 30 Only 10 R 2503 Fan Control 11 R 2805 ...

Page 22: ...e 22 R 3450 Service Notes Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62222 0529 PH 1 800 851 3153 FAX 1 800 443 8648 E MAIL empire accessus net WEB SITE www empirecomfort com ...

Reviews: