Page 32
Installation and Operation Manual - Gateway 2300
ENGLISH
8.1.4 With Heat Shield AC02710 or AC02762 and Lowered Ceiling
17
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
5" (127 mm)
5" (127 mm)
D
8 ¼" (210 mm)
8 ¼" (210 mm)
B
6" (152 mm)
6" (152 mm)
E
15 ¼" (387 mm)
15 ¼" (387 mm)
C
5" (127 mm)
5" (127 mm)
F
14 ½" (368 mm)
14 ½" (368 mm)
L
80" (2030 mm)
80" (2030 mm)
8.1.5 Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
18
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
10" (254 mm)
10" (254 mm)
D
13 ¼" (337 mm)
13 ¼" (337 mm)
B
19" (483 mm)
19" (483 mm)
E
28 ¼" (718 mm)
28 ¼" (718 mm)
K
48" (1220 mm)
36" (910 mm)
L
77" (1960 mm)
77" (1960 mm)
8.1.6 Mobile Home
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
12" (305 mm)
12" (305 mm)
D
15 ¼" (387 mm)
15 ¼" (387 mm)
B
18" (457 mm)
18" (457 mm)
E
27 ¼" (692 mm)
27 ¼" (692 mm)
C
11" (279 mm)
11" (279 mm)
F
20 ½" (521 mm)
20 ½" (521 mm)
17
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
18
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.