Page 30
Installation and Operation Manual - Gateway 2300
ENGLISH
8.1 Clearances
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
15 ½" (394 mm)
12" (305 mm)
A
7" (178 mm)
7" (178 mm)
B
17" (432 mm)
16" (406 mm)
B
17" (432 mm)
16" (406 mm)
C
10" (254 mm)
10" (254 mm)
C
7" (178 mm)
7" (178 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
13
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
19" (483 mm)
15 ½" (394 mm)
D
10 ¼" (260 mm)
10 ¼" (260 mm)
E
26 ½" (673 mm)
25 ½" (648 mm)
E
26 ¼" (667 mm)
25 ¼" (641 mm)
F
19 ¾" (502 mm)
19 ¾" (502 mm)
F
16 ½" (419 mm)
16 ½" (419 mm)
8.1.1 With Heat Shield AC02710 or AC02762
14
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
6 ¼" (159 mm)
6 ¼" (159 mm)
B
4" (102 mm)
4" (102 mm)
E
13 ¼" (337 mm)
13 ¼" (337 mm)
C
3" (76 mm)
3" (76 mm)
F
12 ½" (318 mm)
12 ½" (318 mm)
13
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.
14
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.