background image

 

3  Installation 

This chapter describes how to install the DA hardware in step-by-step instructions.  

Preparing for Installation 

Make sure the following are prepared prior to DA installation: 

 

Tools 

 

Materials 

 

Cables and Wires 

 

Package Inspection 

Tools 

For the installation of the DA, prepare the following tools: 

 

Anti-static wrist strap 

 

Anti-static gloves 

 

Cutting pliers 

 

Wire cutters 

 

Electrical cable crimping pliers 

Materials 

For the installation of the DA, prepare the following materials: 

 

Insulation tape 

 

Wire buckles 

 

Wire labels 

Cables and Wires 

For the installation of the DA, prepare the following cables: 

 

Backup power cable 

The backup power cable and main power cable are required to have matching 
specifications. 

Summary of Contents for KB-DA4060

Page 1: ...KB DA4060 High Efficiency Power Amplifier User Manual M_2000060690_EN_1 1 Easy Installation Easy Info Reading Easy Access Control Easy Maintenance...

Page 2: ...contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Honeywell shall have no liability for any error or damage of any kin...

Page 3: ...dled This sign means to alert the user of important operation and maintenance instructions Caution To avoid electrocution do not use polarized plug with an extension cord receptacle or other outlet un...

Page 4: ......

Page 5: ...gh too low or fluctuates too drastically it is recommended to install a stable AC power source The appliance is not waterproof Do not expose the appliance to rain or moisture and avoid splashing it wi...

Page 6: ...lightning safety logos to prevent an electric shock When the power is turned on do not physically alter the appliance to avoid damaging the equipment Honeywell assumes no liability for appliance malfu...

Page 7: ...Introduction 1 Audience 1 How to Use This Manual 2 1 Introduction 3 Features 3 Functions 3 Power Supply Protection 3 Overheating Protection 4 Overload and Short Circuit Protection 4 Fault Detection a...

Page 8: ...iv Grounding Cable 9 Audio Input Cable 10 Output Cable 11 Completing Installation and Commissioning 12 Precautions 13 4 Technical Specifications 14 5 Packing List 15...

Page 9: ...ures functions and applications Chapter 2 Package Contents Package content details of the KB DA4060 High Efficiency Power Amplifier Chapter 3 User Interface KB DA4060 High Efficiency Power Amplifier f...

Page 10: ...using the KB DA4060 High Efficiency Power Amplifier and pay close attention to all warnings and instructions Keep this manual for later use and reference This manual has been reviewed to ensure its a...

Page 11: ...CLASS D power amplifier with high efficiency and energy conservation Contains four independent channels The rated output power of each channel is 60W Each channel has 100V or 70V of output Supports b...

Page 12: ...o high Overload and Short Circuit Protection When the DA power supply detects a circuit overload or if a short circuit occurs the DA automatically disconnects the power The DA remains protected and si...

Page 13: ...ent In this case the light turns yellow 6 CLIP Peak clipping indicator light When the input signal exceeds the rated peak value the indicator light turns red 7 SIGNAL Signal indicator light This light...

Page 14: ...ble 4 for port PIN descriptions 2 Cooling fan 3 Audio input and control ports FAULT A If a DA fault occurs it is protected or it is self tested ports A and B experience a short circuit B CH1 CH2 CH3 C...

Page 15: ...output voltage is VCC 12V 24V the DA is being self tested When the DA has no input voltage the DA is working normally 9 Balanced positive input of CH4 10 Balanced negative input of CH4 11 DA fault inf...

Page 16: ...installation of the DA prepare the following tools Anti static wrist strap Anti static gloves Cutting pliers Wire cutters Electrical cable crimping pliers Materials For the installation of the DA pre...

Page 17: ...t are intact see Chapter 2 If an item is missing please contact the appropriate vendor Connecting the Cables These cables include the grounding cable main and backup power cables audio input cable and...

Page 18: ...t Use Terminal blocks Notice If the audio input cable is supplied by the installation personnel the cable must be shielded DA has a balanced input connection A balanced connection is recommended to re...

Page 19: ...2 Connecting the input cables to the input terminal 3 Connect the input terminals to their corresponding input ports as shown in Figure3 Figure 3 Connecting the input terminals Output Cable 1 Pull th...

Page 20: ...ompleting Installation and Commissioning Once the DA hardware and cables are installed complete the following commissioning procedures 1 Set the audio volume to a minimum level 2 Press the DA front pa...

Page 21: ...Cables section for more information Pay particular attention to which audio input source is selected and configure the output signal level appropriately as this can save electricity Do not connect the...

Page 22: ...hm Signal to noise ratio 88dB with A Weight Non linear distortion 0 1 at 1 3 rated power 1kHz Indicator lights 1 power indicator light 4 signal lights 4 peak clipping lights 4 equipment protection lig...

Page 23: ...15 5 Packing List Name Quantities KB DA4060 High Efficiency Power Amplifier 1 Audio input connector 2 Audio output connector 2 Safety shield 1 Screws 2 AC power cable 1 Product manual 1...

Page 24: ......

Page 25: ...Co Ltd No 257 Junye Road Guangzhou GETDD East 510530 China Phone 86 20 2839 9600 Fax 86 20 2839 8706 Website www empertech com Manual_KB D Series_EN1 0 Sep 2011 Subject to change without notice 2011 H...