electrical shock.
range
INSTALLATION:
USE ONLY WITH RANGE HOOD CORD CONNECTION KITS THAT HAVE BEEN
INVESTIGATED AND FOUND ACCEPTABLE FOR USE WITH THIS MODEL
RANGE HOOD. A UTILISER SEULEMENT AVEC UNE TROUSSE DE
RACCORDEMENT DE CORDON DE HOTTE VERIFIEE ET APPROUVEE
POUR EMPLOI AVEC CE MODELE DE HOTTE.
INSTALLATION REQUIREMENT
1. Do not install the range hood where there are many doors ro windows
in
order to avoid effecting the exhaust efficiency of the hood that caused
by air convection. (fig.1)
2. Install the range hood right above the cooking surface. The recommended
distance between the cooking surface and the lower edge of the range hood is
minimum 27.56" to maximum 31.5". (Fig.2)
3. In order to get the best performance, do not extend the vent pipe too long,
and try to make the bend of the vent pipe less and straight, make sure the vent
pipe connection is firm and air proof. (Fig.3)
4
.
After hanging the range hood on the wall, make sure the hood is level and
vertical. (Fig.4)
5. The air Outlet is not allowed to connect to chimney flues or combustion gas
ducts. The air outlet should under no circumstances be connected to ventilation
ducts for room in which fuel-burning appliances are installed.