![Empava EMPV-12GC29 Instruction Manual Download Page 9](http://html1.mh-extra.com/html/empava/empv-12gc29/empv-12gc29_instruction-manual_2403416009.webp)
Trouble Shooting
Problem
Corrective action
• There is no spark when lighting the gas
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been replaced
correctly, e.g. after cleaning.
• The gas ring burns unevenly
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been replaced
correctly, e.g. after cleaning.
Instructions for the Installer
Overall dimensions
For Model
Width
Depth
EMPV-12GC29
12in
21in
Cut out dimensions
For Model
Width
Depth
EMPV-12GC29
10.62in
19.21in
Technical Data
Burner configuration
NG
Propane
Nozzles Dia. (mm)
Btu/hr
Nozzles Dia. (mm)
Btu/hr
Ultra-rapid burner
1.64
11500
1.01
11500
Auxiliary burner
0.94
4000
0.62
4000
Gas Type Manifold pressure :
NG gas pressure at 4.0 in wc
LPG gas pressure at 10 in wc.