Identification
© 2019 EMP, Inc.
8
EMP Oil Pump Model Codes
Example:
OP80-24V-EA-L
OP 80 - 24V - E A - L [OEM] [Cert] [Suffix]
1
2
3 4
5
6
7 8
9
10
11
12
1
Component
OP = Oil Pump
5
Voltage
12V = 12 volt
24V = 24 volt
9
I/O
Omit if n/a
A = Address Input
C = Temperature Input
B = Address or Temp Input
(Specified in Calibration)
M = PWM High (modulated)
L = PWM Low (modulated)
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
2
Scavenge Flow Rate
In 0.1 gallons per minute
35 = 3.5 gpm (13.2 lpm)
Omit for single stage pumps
6
Mounting
E = External Mount
C = Cartridge Mount
10
OEM
Omit if n/a
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
3
Pressure Flow Rate
In 0.1 gallons per minute
30 = 3.0 gpm (11.4 lpm)
40 = 4.0 gpm (15.1 lpm)
80 = 8.0 gpm (30.3 lpm)
7
Orientation (degrees)
A = 0
B = 90
C = 180
D = 270
11
Certification
Omit if n/a
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
4
Communication
C = CAN
Omit for on/off or PWM
8
Relief Valve Cracking
Pressure
Omit if n/a
12
Suffix
Omit if n/a
Denotes model variation
–––––––––––––––––––––––
–––––––––––––––––––––––
–––––––––––––––––––––––
OP80-24V-EA-L
= Oil Pump. Single stage, 8.0 gpm pressure, on/off/PWM communication, 24 Volt External
Mount at 0 degrees, no relief valve, uses PWM Low input for commands.
NOTE:
Not every option combination is available.
NOTE:
All current pump models are optimized for use with lighter weight oils like ATF. Performance will be
reduced for heavier weight oils.