64
Software index
Emotron AB 01-3990-11r3
Note: 1. Energy Saving Mode is available only in Volts/Hz Mode (0-00 = 0002).
3-18
Copy Unit
0000: Disable
0001: VSD to Copy Unit
0002: Copy Unit to VSD
0003: Verify
0000
3-19
Fan Control
0000: Auto (depends on
temp.)
0001: Operate while in
RUN mode
0002: Always Run
0003: Always Stop
0000
3-20
Energy Saving Mode *
1
0000: Disabled
0001: Controlled by
MFIT at Set Frequency
0000
*6
3-21
Energy Saving Gain (%)*
1
0 to 100
80
*6
3-22
Carrier Frequency (kHz)
2 to 16
10
3-23
Centre Frequency (CF) of
Traverse Run (%)
5.00 to 100.00
20.00
3-24
Amplitude (A) of Traverse
Run (%)
0.1 to 20.0
10.0
3-25
Drop (D) of Traverse Run (%) 0.0 to 50.0
0.0
3-26
Acc Time (AT) of Traverse
Run (s)
0.5 to 60.0
10.0
3-27
Dec Time (DT) of Traverse
Run (s)
0.5 to 60.0
10.0
3-28
Rise (X) Deviated Traverse
(%)
0.0 to 20.0
10.0
3-29
Lower (Y) Deviated Traverse
(%)
0.0 to 20.0
10.0
3-30
Start Frequency (Hz)
0.00 to 10.0
0.0
Function
Code no.
Description
Range/Code
Factory
setting
Re-
marks
Summary of Contents for VSC 48-009
Page 1: ...Emotron VSC Variable Speed Drive Quick Setup Guide Multilingual...
Page 3: ...Emotron AB 01 3990 11r3...
Page 15: ...14 Anmerkungen zur Verkabelung Emotron AB 01 3990 11r3...
Page 38: ...Emotron AB 01 3990 11r3 Programmierungsanweisungen und Men liste 37...
Page 130: ...Emotron AB 01 3990 11r3 Localizaci n de aver as y mantenimiento 129...
Page 142: ...Emotron AB 01 3990 11r3 Kabelaansluitingen 141...
Page 163: ...162 Programmeringsinstructies en Menulijst Emotron AB 01 3990 11r3...
Page 182: ...Emotron AB 01 3990 11r3 Kabeldragning 181...
Page 209: ...208 Fels kning och underh ll Emotron AB 01 3990 11r3...