3
GB | Thermostat
The P5604 thermostat is designed for controlling heating and air-con-
ditioning systems.
Important
• Before the first use, make sure to carefully read the Operating
Manual for the thermostat, as well as the boiler or air-conditioning
equipment.
• Turn off power supply before installing the thermostat!
• Installation should be carried out by a qualified person!
• During installation, follow applicable standards.
Technical specifications:
Switched load: max. 230 V AC; 8 A for resistive load; 2 A for inductive
load
Clock accuracy: ±60 seconds/month
Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution
accuracy ±1 °C at 20 °C
Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Temperature differential: 0.2 °C
Operating temperature: 0 °C to 40 °C
Storage temperature: -20 °C to 60 °C
Power supply: 2× 1.5 V AAA batteries
Accessories: 2 screws, 2 wall plugs
Dimensions and weight: 30 × 120 × 75 mm; 125 g
Display Description
(See Fig. 1)
1 – Operating mode
2 – Cooling mode
3 – Low battery indicator
4 – Current set temperature
5 – Room temperature
6 – Heating mode
Procedure for Removing the Front of the Thermostat
(See Fig. 2)
Display Backlighting
Pressing the control wheel activates display backlighting for 10 seconds.
INSTALLATION
Warning:
Before replacing the thermostat, disconnect the heating/air-conditioning
system from the main power in your flat. This will prevent potential injury
by electric current.
Summary of Contents for P5604
Page 2: ...2 1 2 3 6 4 5 1 2...
Page 32: ...32 1 5 2 a HEAT b OFF 7 C c COOL 3...
Page 49: ...49 b OFF 7 C c COOL 3...
Page 50: ...50 http www emos eu download...
Page 51: ...51...