• The device may only be operated by a responsible and trained person.
• Do not test voltage through contact if you do not know the exact voltage in the circuit!
• ATTENTION! Measurement time must not be longer than 10 seconds, especially in higher
voltages.
• The maximum measurement time must not exceed 30 seconds or the device will become
damaged.
• A 240 second pause must follow after each measurement.
• When measuring, hold the probe behind the mechanical barrier on the tester body. This
will prevent accidental contact with the metal portion of the probe, which could otherwise
cause injury by electric current during measurement.
• The voltage listed on the tester is rated voltage. The tester may only be used on electrical
installations with the listed rated voltage.
• The tester can only be used for testing voltages above the ELV (extra low voltage) threshold.
• The tester must be checked before and after testing. The tester must not be used if the
indicators on the tester are failing.
• Do not modify the measuring tips or any other parts of the tester. If the tester is malfunc-
tioning or otherwise damaged, have it repaired in a professional repair shop.
• Do not use the tester if its components are wet.
International Electrical Symbols
alternating current (AC)
direct current (DC)
alternating or direct current
earthing
double insulation
warning, risk of danger. Read all sections of the manual where this symbol is used!
risk of injury by electric current
declaration of conformity (CE)
This device is not intended for use by persons (including children) whose physical, sensory or
mental disability or lack of experience and expertise prevents safe use, unless they are supervised
or instructed in the use of the appliance by a person responsible for their safety. Children must
always be supervised to ensure they do not play with the device.
Do not dispose with domestic waste. Use special collection points for sorted waste.
Contact local authorities for information about collection points. If the electronic devic-
es would be disposed in landfill, dangerous substances may reach groundwater and
subsequently food chain, where it could affect human health.
You can request technical support from the supplier: