8
The resulting diameter of the conductors is as shown in the table:
Conductor core diameter [mm]
Distance [m]
0.5
20
0.65
50
0.8
70
1
115
In basic implementation, there is no need to use a coaxial cable to transmit the video component.
Such a cable is only recommended for distances over 100 m.
For long ground cabling, you can use a telecommunication cable of category TCEPKPFLE.
Basic Operation of the Device
To ring the bell and call up the image from the door camera unit
on the videophone, press the button on the door camera unit.
Audio from outside will also be transmitted to the monitor.
To accept a call, press this button on the monitor:
Maintenance of the Device
The device is low-maintenance. It is recommended, based on the condition of the device, to occasionally wipe the device down with
a moistened cloth.
Attention! Before cleaning, the device must be disconnected from power!
FAQ
The image/sound is not clear, the device does not ring
Remove the monitor or the door camera unit and connect it using a short cable to eliminate the possibility of a interrupted conductor
in the house.
Then check the image and sound settings (brightness, contrast, colour, volume).
The lens steams up
This occurs mainly during cold weather, where condensation occurs due to the temperature difference between the wall and the door
camera unit itself. If water condenses on the lens, we recommend thoroughly drying the door camera unit and adjusting the installation.
Spontaneous ringing
Spontaneous ringing is caused by moisture entering the door camera unit. Water short-circuits the contacts on the lock switch and
the device will start ringing on its own. We recommend dismounting the door camera unit, drying it thoroughly and spraying it with a
water repellent for electronics.
High-pitched noise (feedback)
The source of feedback is the scattering of output sound from the door camera unit. The sound scatters and is fed back into the
microphone, where it is further amplified.
Summary of Contents for H3016
Page 2: ...2 1A...
Page 3: ...3 1B...
Page 4: ...4 1C...
Page 5: ...5 2 140 170 cm 40 cm 3...
Page 30: ...30 UA 1 RFID 125 5 1 1 1 12 B 2 3 GND 4 2 5 12 B 6 7 3 8 12 B 9 10...
Page 32: ...32 FAQ 12 EMOS spol s r o H3016 H3017 H3018 http www emos eu download...
Page 47: ...47 12 V EMOS spol s r o H3016 H3017 H3018 http www emos eu download...