3
GB | Wireless Sensor
Technical Specifications
outdoor temperature: -30 °C to +60 °C, 0.1 °C resolution
temperature measurement accuracy:
±1 °C for 20 °C to +24 °C range,
±2 °C for 0 °C to +20 °C and 24 °C to +40 °C range,
±3 °C for -20 °C to 0 °C and 40 °C to +50 °C range,
±4 °C for other ranges
indoor and outdoor humidity: 1–99 % RH, 1 % resolution
humidity measurement accuracy: 5 %
wind sensor measurement range: 0 to 127.5 km/h
unit of wind speed: km/mph
precipitation sensor measurement range: 0 to 2,999 mm
unit of precipitation: mm/inch
radio signal range: up to 100 m in an open space
transmission frequency 433 MHz, 10 mW e.r.p. max.
temperature/humidity/wind sensor power supply: 4× 1.5 V AA (not included)
temperature/humidity/wind sensor dimensions and weight: 275 × 135 × 310 mm, 377 g (without
batteries)
Sensor Description
See fig. 1
1 – wind sensor cups
2 – compass
3 – wind direction paddle
4 – temperature/humidity/wind sensor battery compartment
Buttons: TX – send signal from sensor to station,
1/2/3 – switch sensor channel number,
WAVE – manual activation/deactivation of DCF signal reception
5 – mounting rod (26 mm diameter)
6 – mounting base
Station Description
See fig. 2
1 – CHANNEL button
– search for sensor signal/browse through readings from individual con-
nected sensors
2 – power adapter socket
3 – battery compartment
Getting Started/Installation
1. Connect the adapter to the station, then insert batteries first into the weather station (3× 1.5 V
AAA), then into the wireless temperature/humidity/wind sensor (4× 1.5 V AAA).
2. When inserting the batteries, make sure the polarity is correct to avoid damaging the weather
station or sensor. Only use alkaline batteries of the same type; do not use rechargeable batteries.
3. Place the two units next to each other. The weather station will automatically detect the signal
from sensors within 3 minutes. If signal from sensors is not detected, long-press the CHANNEL
button on the weather station to repeat the search and press the TX button on the sensor.
4. To ensure correct measurement, the temperature/humidity/wind sensor and precipitation
sensor must be placed above the ground (at least 1.5 m) onto a horizontal surface and outside
of buildings and structures. The sensor must be mounted firmly to prevent its damaging. First,
screw the mounting plate onto a level surface, then mount the mounting rod into it. Screw the
temperature/humidity/wind sensor onto the rod. Wind must flow freely around the wind sensor
from all sides. Check that the wind direction indicator and paddles for measuring wind speed can
Summary of Contents for E06016