emmeti XECO-0915E Installation Manual And User Instructions Download Page 34

34

1. DESCRIZIONE DEI COMPONENTI

IT

IT

GB

GB

f) In kitchens with a lot of oil fumes and with high humidity percentage

g) Near machines issuing electromagnetic waves

h) Places with acid or alkaline fumes

TV, radio, acoustic equipment have to remain at a minimum distance of 

1 m from the internal unit, the external unit, the power supply cables, 

pipes; otherwise images could result not clear and some noise could be 

detected.

Air conditioner has to be placed in a well-ventilated and easy to reach place.

Air conditioner has not to be placed in the following places:

a) Places where there are machines oils or other oils fumes.

b) Along the coast with high salt concentration in the air

c) Near resurgences with high content of sulphuric gases

d) In areas with high tension fluctuation, e.g. factories etc.

e) In vehicles or boats

5.1  External unit positioning

If possible, avoid exposing the unit to direct 

sunlight, particularly in early afternoon.

On the contrary, provide for a suitable protection 

that does not obstruct the free circulation of air.

Avoid positioning in correspondence with areas 

that can worsen the negative effects of atmo-

spheric agents such as eaves drains or downpipe 

drains.

Select the position that is favourable for air 

circulation and facilitates the drain of the con-

densation water.

In the models pay particular attention to snowfall, 

including snow falling from roof pitches which 

could obstruct air circulation.

Select a position in which noise and the air jet do 

not damage or bother people, animals or plants.

Make sure the “minimum operational distances” 

are observed.

5. UNIT POSITION

5.2  Minimum functional distances of the external unit

> 500 mm

> 500 mm

> 1000 mm

> 2000 mm

> 500 mm

Summary of Contents for XECO-0915E

Page 1: ...IONE ED ISTRUZIONI PER L USO IT IT INSTALLATION MANUAL AND USING INSTRUCTIONS INSTALLATION MANUAL AND USING INSTRUCTIONS GB GB MANUAL INSTALACI N E INSTRUCCIONES PARA EL USO MANUAL INSTALACI N E INSTR...

Page 2: ...tate e per la validit della garanzia Attenzione Conservare i manuali in luogo asciutto per evitare il deterioramento per even tuali riferimenti futuri GB GB page 27 Thanks you for the trust you have s...

Page 3: ...o dell unit esterna 5 2 Distanze minime funzionali unit esterna 5 3 Distanze fra le unit 5 4 Dati dimensionali unit esterna 6 INSTALLAZIONE DELL UNIT ESTERNA 13 6 1 Installazione dell unit esterna 6 2...

Page 4: ...e A parete 07 XECO 0715W 09 XECO 0915W 12 XECO 1215W 18 XECO 1815W 24 XECO 2415W Canalizzata 09 XECO 0915D 12 XECO 1215D 18 XECO 1815D 24 XECO 2415D Cassette 12 XECO 1215C 18 XECO 1815C 24 XECO 2415C...

Page 5: ...qua sopra l unit Controllare la solidit del fissaggio del climatizzatore Non appoggiare oggetti e non salire sull unit Non indirizzare il flusso dell aria direttamente sulle persone piante e animali L...

Page 6: ...ola molto pericolosa e pu provocare lesioni Evitare l utilizzo di apparecchi di riscaldamento in prossimit del climatizzatore Scegliere la temperatura ambiente pi adatta Attenzione a locali occupati d...

Page 7: ...fluor s effet de serre pr vus par le protocole de Kyoto Ne pas laisser les gaz s chapper dans l atmosph re Kg Kg Kg R 410 A 1 1 2 2 2 2 1 1 1 1 2 2 B C F E A D IT IT Questo prodotto contiene gas fluor...

Page 8: ...i originali Prodotti incompatibili esplosivo ateriali infiammabili Organic peroxide Controllo della esposizione protezione individuale Parametri di controllo AEL 8 h TWA 1000 ml m per ciascuno dei due...

Page 9: ...disimballo devono essere eseguite con cura al fine di non danneggiare l involucro delle unit se si opera con coltelli o taglierini per aprire l imballo in cartone Dopo aver tolto l imballo assicurars...

Page 10: ...fluttuazione della tensione e g fabbriche eccetera 5 1 Posizionamento dell unit esterna Evitare un posizionamento in corrispondenza di zone che possano accentuare gli effetti negativi degli agenti atm...

Page 11: ...15QE 10 10 20 70 40 20 XECO 4216CE 7 5 15 25 80 50 22 5 3 Distanze fra le unit Nota pi corto il tubo del refrigerante migliori sono le prestazioni Collegare in modo che il tubo sia il pi corto possibi...

Page 12: ...257 510 286 XECO 1215E 776 540 320 712 257 510 286 XECO 1815E 963 700 396 892 341 560 368 XECO 2415E 1000 790 427 920 370 610 395 XECO 1415DE 903 596 378 838 303 550 340 XECO 1815DE 963 700 396 892 34...

Page 13: ...e consigliabile avere la possibilit di un controllo visivo dello scarico al termine della tubazione oppure inserire uno spezzone trasparente nella tubazione stessa quando questa confluisce in uno scar...

Page 14: ...14 XECO 1415DE 2 x 1 4 2 x 6 35 2 x 3 8 2 x 9 52 Multi x2 18 XECO 1815DE 2 x 1 4 2 x 6 35 2 x 3 8 2 x 9 52 Multi x3 24 XECO 2415TE 3 x 1 4 3 x 6 35 3 x 3 8 3 x 9 52 Multi x4 28 XECO 2815QE 4 x 1 4 4...

Page 15: ...bi ai raccordi Connettere le tubazioni ai raccordi delle unit Per il serraggio stringere i bocchettoni con una coppia pari a Collegare il cavo di messa a terra Il cavo di messa a terra non deve essere...

Page 16: ...ascette Utilizzare un cavo multipolare del tipo N07RN F Per lunghezze superiori ai 15 m adottare le sezioni standard immedia tamente superiori sempre verificando che in ogni caso la caduta di tensione...

Page 17: ...mentazione Alimentazione Unit Interna D Unit Interna C Unit Interna B Unit Interna A XT5 XT4 XT3 XT2 XT1 N L Alimentazione XT5 1 T X 2 T X 3 T X 4 T X 6 T X N L Unit Interna D Unit Interna E Unit Inte...

Page 18: ...cuometro attendere almeno 5 minuti per verificare che il vuoto nell impianto sia mantenuto altrimenti ricercare la causa della perdita Per linee oltre i 5 metri indispensabile caricare il circuito med...

Page 19: ...interne Dopo aver fatto funzionare l unit per 20 minuti misurare il delta T dell unit interna Nota se la temperatura ambiente inferiore a 16 C impossibile eseguire il test di funzionamento in modo Raf...

Page 20: ...pento e staccate la spina dalla presa di corrente Il refrigerante contenuto all interno richiede una speciale procedura per lo smaltimento I materiali di valore contenuti nel climatizzatore possono es...

Page 21: ...cheda elettronica unit esterna danneggiata 11 Frequenza ridotta per sovratemperatura del modulo IPM EU 1 Verificare l isolante termico del Modulo IPM e il radiatore l unit deve essere disalimentata da...

Page 22: ...fissa P1 Visualizzato durante i test a frequenza fissa P1 27 Test a frequenza fissa P2 Visualizzato durante i test a frequenza fissa P2 28 Test a frequenza fissa P3 Visualizzato durante i test a freq...

Page 23: ...ccoppiate 46 Mancato avvio LC 1 Tempo di rispetto del compressore 2 Cablaggio del compressore allentato o tranciato 3 Compressore danneggiato 47 Anomalia corrente di fase rilevata al circuito del comp...

Page 24: ......

Page 25: ...per utente Da conservare compilare in stampatello in modo chiaro e leggibile CERTIFICATO DI GARANZIA Tagliando A Modello apparecchio Matricola unit interna Data installazione prima accensione Utente...

Page 26: ...tanafredda PN la parte C entro 10 giorni dalla data di installazione prima accensione In caso di mancato invio del certificato entro 10 giorni dalla installazione prima accensione dell apparecchio o q...

Page 27: ...ler Date installation first running Model Chiller N Code Chiller Date installation first running Rev 0 02 2010 Rev 0 02 2010 Rev 0 02 2010 GB GB INDICE 8 DISPOSAL 44 8 MALFUNCTIONE 45 9 PRODUCT FICHE...

Page 28: ...hich has to be air conditioned All functions of the air conditioner are activated by an infrared remote control 1 2 Internal unit Air inlet grille 2 Air outlet grille 3 Electrical connection 4 Connect...

Page 29: ...he air flow directly on individuals plants or animals Unit is not intended to be used by persons with reduced physical sensory or mental abilities or with lack of experience or acknowledge children in...

Page 30: ...of the fan is very dangerous and can cause injury Avoid the use of heating equipments near the air conditioner Select the most suitable room temperature Be careful in rooms where there are children si...

Page 31: ...FR Ce produit contient des gaz fluor s effet de serre pr vus par le protocole de Kyoto Ne pas laisser les gaz s chapper dans l atmosph re Kg Kg Kg R 410 A 1 1 2 2 2 2 1 1 1 1 2 2 B C F E A D IT IT Qu...

Page 32: ...losives inflammable materials Organic peroxide Exposure controls personal protection Control parameters AEL 8 h TWA 1000 ml m for each of the two components Respiratory protection For gas recovery and...

Page 33: ...les Unpacking operations have to be done carefully because the external part of the units has not to be damaged when knifes or cutters are used to open the carton package After unpacking make sure of...

Page 34: ...with high tension fluctuation e g factories etc e In vehicles or boats 5 1 External unit positioning If possible avoid exposing the unit to direct sunlight particularly in early afternoon On the contr...

Page 35: ...80 50 22 5 3 Distance between the units Note the shorter the refrigerant pipe the better the performance Connect so that the pipe is as short as possible The minimum length for the room is 3 m Multi...

Page 36: ...6 540 320 712 257 510 286 XECO 1215E 776 540 320 712 257 510 286 XECO 1815E 963 700 396 892 341 560 368 XECO 2415E 1000 790 427 920 370 610 395 XECO 1415DE 903 596 378 838 303 550 340 XECO 1815DE 963...

Page 37: ...tion water outlet so that no damage may be caused to people or things It is advisable to be able to visually check the outlet drain at the end of the piping or alternatively insert a transparent secti...

Page 38: ...1 x 15 88 6 3 Refrigerating circuit piping The connections for the refrigerating piping are sealed with a flared end and flare nut The outdoor unit contains the whole charge of the refrigerating syste...

Page 39: ...units make sure that the main electrical supply has been disconnected Before interrupting the power supply by means of the switch turn the air conditioner off with the remote control Refrigerant oil F...

Page 40: ...he units For al models power supply is moved to external unit Use a power source for the exclusive use of the air conditioner with circuit breaker differential dedicated 6 4 3 Connection and alimentat...

Page 41: ...l unit Single Terminal block external unit Trial XECO 2415TE x 3 L A B C Alimentation Cable Alimentation Cable Alimentation Cable Alimentation Cable N 1 2 3 Connection cable Cable gland Alimentation C...

Page 42: ...inutes then check that the vacuum in the system has been maintained If not look for the cause of the leak For pipelines longer than 5 meters it is necessary to fill the circuit using a measuring cylin...

Page 43: ...impos sible to test the operation in Heating mode Note When unit stops or operating mode has been changed the com pressor does not start working before 3 min When operating in Cooling mode some frost...

Page 44: ...nt it contains requires a special procedure for dis posal Materials of value in the air conditioner can be recycled Contact local authorities or the waste disposal facility for more information Make s...

Page 45: ...ion since the air conditioner is equipped with a thermal sensor inserted in the coil of the indoor unit which optimizes the operation of the fan till a temperature of 38 C is reached It is a normal si...

Page 46: ...l insulation of the IPM module and the radiator the unit must be off for at least 20 minutes 2 2 Outdoor unit AP1 electronic board damaged 12 Bridge anomaly C5 The bridge on the electronic board of th...

Page 47: ...the P4 fixed frequency test 30 Fixed frequency test P5 Displayed during the P5 fixed frequency test 31 Fixed frequency test P6 Displayed during the P6 fixed frequency test 32 Fixed frequency test P7 D...

Page 48: ...urrent anomaly detected in the compressor circuit U1 1 Voltage between L and N on the terminal board different from 210 250 VAC 2 Compressor wiring loose or cut 3 Compressor damaged 4 Outdoor unit AP1...

Page 49: ...49 1 DESCRIZIONE DEI COMPONENTI Fontanafredda Pn Italy Fontanafredda Pn Italy SCHEDA PRODOTTO PRODUCT FICHE GB GB IT IT...

Page 50: ...50 1 DESCRIZIONE DEI COMPONENTI GB GB IT IT Fontanafredda Pn Italy Fontanafredda Pn Italy SCHEDA PRODOTTO PRODUCT FICHE...

Page 51: ...51 1 DESCRIZIONE DEI COMPONENTI GB GB IT IT 11 SCHEDA PRODOTTO PRODUCT FICHE Fontanafredda Pn Italy Fontanafredda Pn Italy...

Page 52: ...52 1 DESCRIZIONE DEI COMPONENTI SCHEDA PRODOTTO PRODUCT FICHE GB GB IT IT Fontanafredda Pn Italy DE Fontanafredda Pn Italy QE...

Page 53: ...53...

Page 54: ...BK BN 8 9 6 7 29 203 5 3 3 0 1 2 1 1 1 32 5 1 1 7 7 50 1 29 5 2 5 3527 725 203 203 5 8 9 8 3 1 225 81 7 JURXQG RQO LURQ VKHOO PRWRU DSSOLHV WR WKH 0RWRU 127 02725 XECO 1815E XECO 2415E vedi leggenda a...

Page 55: ...UHYHQW WKH ULVN RI HOHFWULFDO VKRFN 51 1 3 1 3 9 9 7521 3 16 21 3 16 21 7521 9 9 1 1 5 5 XECO 1815DE vedi leggenda a p 58 see legend p 58 5 1 1 9 9 7521 3 16 21 3 16 21 7521 9 9 3 1 3 51 1 3OHDVH GRQ...

Page 56: ...2035 6625 9 9 9 211 725 97 97 3 5 5 5 8 8 9 29 203 33 7 6 1625 7 9 9 3 16 21 7521 9 1 1 20 11 5 9 9 9 5 2 8 7521 3 16 21 9 9 3 16 21 7521 7521 3 16 21 9 9 5 725 XECO 2415TE vedi leggenda a p 58 see le...

Page 57: ...57 1 DESCRIZIONE DEI COMPONENTI 9 SCHEMI ELETTRICI XECO 4216CE vedi leggenda a p 58 see legend p 58 GB GB IT IT SCHEMI ELETTRICI ELECTRIC SCHEMES...

Page 58: ...HEAT None stripping compressor band heater doesn t need the connection wiring ter minals No W23 line and N0 W24 line are replaced by the two lead out wires equipped with band heater connected to the A...

Page 59: ...xchanger C heat exchanger D heat exchanger filter filter filter filter C2 C3 D3 D2 B3 B2 A2 A3 A1 A unit electronic expansion valve B1 B unit electronic expansion valve C1 C unit electronic expansion...

Page 60: ...AP high pressure switch Scambiatore di calore unit esterna outdoor heat exchanger A1 A valvola di espansione elettronica dell unit B1 B valvola di espansione elettronica dell unit A1 A unit electroni...

Page 61: ...reet Zip Town Country Slip A for user To be kept Please print in block letters GUARANTEE CERTIFICATE Slip A GUARANTEE CERTIFICATE Slip B GUARANTEE CERTIFICATE Slip C Model Serial Number Date installat...

Page 62: ...send part C in a closed envelope to Emmeti Spa post box nr 74 Fontanafredda PN within ten days from the date of installation first startup Should the certificate not be sent within 10 days of the ins...

Page 63: ......

Page 64: ...emmeti com E mail info emmeti com Rev 0 12 2015 Ufficio Tecnico Emmeti Spa AM Rispetta l ambiente Per il corretto smaltimento i diversi materiali devono essere separati e conferiti secondo la normati...

Reviews: