34
1. DESCRIZIONE DEI COMPONENTI
IT
IT
GB
GB
f) In kitchens with a lot of oil fumes and with high humidity percentage
g) Near machines issuing electromagnetic waves
h) Places with acid or alkaline fumes
TV, radio, acoustic equipment have to remain at a minimum distance of
1 m from the internal unit, the external unit, the power supply cables,
pipes; otherwise images could result not clear and some noise could be
detected.
Air conditioner has to be placed in a well-ventilated and easy to reach place.
Air conditioner has not to be placed in the following places:
a) Places where there are machines oils or other oils fumes.
b) Along the coast with high salt concentration in the air
c) Near resurgences with high content of sulphuric gases
d) In areas with high tension fluctuation, e.g. factories etc.
e) In vehicles or boats
5.1 External unit positioning
If possible, avoid exposing the unit to direct
sunlight, particularly in early afternoon.
On the contrary, provide for a suitable protection
that does not obstruct the free circulation of air.
Avoid positioning in correspondence with areas
that can worsen the negative effects of atmo-
spheric agents such as eaves drains or downpipe
drains.
Select the position that is favourable for air
circulation and facilitates the drain of the con-
densation water.
In the models pay particular attention to snowfall,
including snow falling from roof pitches which
could obstruct air circulation.
Select a position in which noise and the air jet do
not damage or bother people, animals or plants.
Make sure the “minimum operational distances”
are observed.
5. UNIT POSITION
5.2 Minimum functional distances of the external unit
> 500 mm
> 500 mm
> 1000 mm
> 2000 mm
> 500 mm