6
IT
IT
1. DESCRIPTION TANKS
GB
GB
Puffer storage tanks for heating water with and without fixed coil
Model
u.m.
300
500
1000
1500
2000
Total capacity (Volume utile)
ℓ
270
476
920
1410
2010
Termocamino delivery
1” 1/2
A
mm
1340
1470
1860
1770
2070
Return thermo fireplace
1” 1/2
A1
mm
600
710
805
850
950
Heating supply
1” 1/2
B
mm
970
1090
1335
1310
1510
Heating return
1” 1/2
B1
mm
230
330
280
390
390
Boiler delivery
1” 1/2
C
mm
1340
1470
1860
1770
2070
Boiler return
1” 1/2
C1
mm
600
710
805
850
950
Third heating source delivery
1” 1/2
D
mm
970
1090
1335
1310
1510
Third heating source return
1” 1/2
D1
mm
230
330
280
390
390
Solar supply (**)
1”
MS
mm
830
930
990
1290
1290
Solar return (**)
1“
RS
mm
230
330
280
390
390
Heating probe
1/2”
RS
mm
-
-
-
-
Solar heating probe
1/2”
SRS
mm
-
-
-
-
Ø with insulation
E
mm
700
850
990
1200
1300
Ø without insulation
F
mm
500
650
790
1000
1100
Height
G
mm
1560
1700
2115
2090
2405
Venting
1”1/4
H
mm
In alto
Serpentine exchange surface (**)
m
2
1,8
1,8
12,6
3,8
3,8
Fixed coil content (**)
ℓ
10,4
10,4
14,6
21,6
21,6
Empty weight (*)
kg
77,5 (95)
105(124)
150 (180)
196(180)
215(260)
Max working pressure of the tank
bar
6
6
6
6
6
Max coil operating pressure (**)
kg
6
6
6
6
6
Maximum tank operating temperature
°C
95
95
95
95
95
E
F
45°
45°
G
Note:
equip the safety valve and expansion tank puffer
adapted to the volume of the system.
Technical data
- Raw tank inside with painted outer surface.
- Insulation: in polyester flexible thickness 100 mm.
- Insulation coating SKY Grey PVC.
- In compliance with directive 2014/68/EU, art. 4.3.
(*) The value of the serpentine model is shown in brackets.
(**) Model with serpentine only.