Tanks Euro HPV
Technical data
- Maximum operating pressure: 10 bar exchanger.
- Maximum continuous operating temperature accumulation: 95 °C.
- Testing pressure: 15 bar.
- Inorganic enamelling (vitrification).
- Insulation: in rigid expanded polyester thickness 50 mm.
for models 200, 300 and 500, in polyurethane thickness 100 mm
model 1000.
- Insulation coating SKY Grey PVC.
- In compliance with directive 2014/68/EU, art. 4.3.
- In compliance with DIN 4753.3 and UNI 10025.
B
R
R
A
C
D
E
F
M
O
P
Q
Q
C
D
E F
G
H
I L
M
O
P
Q
Q
N
N
B
A
HPV200 - HPV300 - HPV500
HPV1000
Note:
in the sanitary circuit near of the boiler must be installed a safety
valve with calibration maximum = 6 bar and the expansion vessel adapted
to the volume of the sanitary system.
Model
Rif.
200 / 300
500
1000
u.m.
Euro
HPV200
Euro
HPV300
Euro
HPV500
Euro
HPV1000
Total capacity
ℓ
190
263
470
900
Ø without insulation
A
mm
500
500
650
790
Ø with insulation
B
mm
600
600
750
990
Height
C
mm
1215
1615
1705
2140
Height whit isolation
mm
1215
1615
1705
2205
Cold water inlet
D
1”
1”
1”1/4
mm
1070
1390
1415
1940
Heat exchanger outlet
E
1”
1”1/4
1”1/4
mm
990
1310
1330
1830
Recirculation
F
1/2”
1/2”
1”
mm
835
1165
1170
1615
Thermostat / Thermometer
G
-
-
1”
mm
-
-
-
1485
Thermostat / Thermometer
H
1/2”
1/2”
1”
mm
370
395
425
515
Outlet fixed serpentine
I
1”
1”1/4
1”1/4
mm
220
220
270
345
Inlet water Cold
L
1”
1”
1”1/4
mm
140
140
185
240
Flange
M
DN 180
DN 180 DN 180
mm
320
340
370
470
Anodo
N
-
-
1”1/2
mm
-
-
-
470
Electrical resistance
O
1”1/2
1”1/2
1”1/2
mm
735
945
970
1435
Thermostat / Thermometer
P
1/2”
1/2”
1/2”
mm
995
1390
1425
1940
Anodo
Q
1”1/2
1”1/2
1”1/2
mm
Up
Up
Up
Up
Hot water outlet
R
1”1/4
1”1/4
-
mm
Up
Up
Up
-
Exchange surface
fixed serpetine
m
2
3,0
4,0
6,0
8,0
Contet
fixed serpetine
ℓ
17,2
23,0
50,5
68,5
Empty weight
kg
120
160
220
320