L
14
Note:
External fuse is recommended.
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While
installing the unit, supply voltage range must be controlled
and appropriate supply voltage must be applied to the unit.
11
N
o
te
3
4
15
14
11 12 13
PTC
PTC
OUTPUT
7A@240V
~
PUMP
1.5VA
8
9 10
OUTPUT
7A@240V
~
HEATER
COLLECTOR
TANK
T1
T2
P1
PUMP
C
O
LL
E
C
TO
R
TANK
HEATER
H1
12
FG
DT-9910
( 96x96 1/4 DIN )
A BC D
E
FG HI
/
/
U
V
W
Z
/
/
0
01 00
2
2
0
3
Supply Voltage
A
4
5
9
2
1
Output-1(Pump Output)
E
InputType
BC
1
1
PTC
P
-50 ile 150
°
C
Serial Communication
D
0
Y
1
1
(OUTPUT-2)
(OUTPUT-1)
1
12
N
L
www.emkoelektronik.com.tr
Temp. Sensor which is given with Controller
V
0
None
2
PTCR-
6.Entering To The Programming Mode, Changing and Saving Parameter
8. Electrical Wiring Diagram
Supply Input Connection
External
Fuse
Supply Voltage
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
important in electrical connection.
External fuse that on
E
phase connection.
External fuse that on Zpower supply inputs must be on
connection.
Note-1:
Temperature sensor is given with thedevice.Therefore, the sensor type code
E
T
! "
#
be selected.
Relay Output
Relay Output
Output-2(Heater Output)
Scale (°C)
Your Technology Partner
Thank you very much for your preference to use
Emko Elektronik products, please visit our web
page to download detailed user manual.
T
P
When button is pressed,set value blinks and T led
W$ %&& '(
) *$ +, -
.' /
*' 0%
& 3&' ,
.' /
/
&
0%
&3 &',
buttons are changed value. After press set button for saving. if do not touch for 3 second,saving
cancelled and returns to the main screen. T led blinks, the set value can be adjusted from 0 -
c5 6
Set value how many degrees the collector temperature greater than tank temperature for activating
the pump.
Set button is pressed once, sensor led lights which one shows on the screen.
if difference between the temperature sensors on the screen, T LED
i
7 8
9
Customer
24V
( ± %15 )
_ _ _
Resistive Load, 1NO + 1NC
R
:
; <
= >?@A
Resistive Load, 1NO + 1NC
R
:
; <
=
>
?@A
Differential Controller
Differential Controller
Differential Controller
Differential Controller
F
FBC
230V
( ± %15 ) 50/60Hz
115V
( ± %15 ) 50/60Hz
24V
( ± %15 ) 50/60Hz
Supply
Switch
Supply
Switch
7. Sensor Value on Main Screen
9. Supply Voltage Input Connection of the Device
Ordering Information