background image

 

 

 

DISPLAY PANEL: 

 

 

 

Message -1  

 

 

 

 

 

Message - 2 

XX.X V INDICATES THE BATTERY VOLTAGE LEVEL AS PER ACTUAL. 

 

Operation: 

 

Do  not  disconnect  Solar  Panel Input  cable  /  mains  cable  of  the SPG system and also the 
power socket outlet during operations since this would nullify the grounding of SPG system and 
all connected loads. 

 

The SPG has its own internal power source (batteries).   The output terminals may be electrically 
live even when the SPG  is not connected to the Solar Panel / AC supply. Hence handle with 
caution. 

 

In case of any Error observed please note down the error code which will get generated and 
displayed in front panel display which will help the service engineers for a quick fix. 

 

 

UPS ON                           MPPT ON 

LOAD

 

                        

BAT XX.X V

 

 

MAINS ON                           MPPT ON 

CHARGER ON

                     

BAT XX.XV

 

 

Summary of Contents for SPG1000W

Page 1: ...SOLAR POWER GENERATOR UNIT USER MANUAL COVERING SPG500W AND SPG1000W 1...

Page 2: ...Each time before using the SPG READ ALL instructions and cautionary markings on or provided with the SPG and all appropriate sections of this guide Safety Precautions to be followed while Installatio...

Page 3: ...calshockhazard FIRE AND BURN HAZARD Do not cover or obstruct the air intake vent openings and or install in a zero clearance compartment Do not use transformer less battery chargers in conjunction wit...

Page 4: ...have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 4 If battery acid contacts skin or clothing wash immediately with soap and water If acid enters your eye...

Page 5: ...F DAMAGE TO THE SPG Never allow battery acid to drip on the SPG when reading gravity or filling battery Never place the SPG unit directly above batteries gases from a battery willcorrodeanddamagetheSP...

Page 6: ...micals gasoline etc Always ensure you connect the SPG system to an earthed shockproof socketoutlet Ensure proper Tools connections for Solar Input to SPG and AC Output fromSPG Please make sure the bat...

Page 7: ...and ensure the Display as in Pic 1 Isometric View Picture 1 Connect AC Mains cable with AC Grid source and ensure the display as in Pic 2 and please do not feed the output of the SPG as the input to...

Page 8: ...system and all connected loads The SPG has its own internal power source batteries The output terminals may be electrically live even when the SPG is not connected to the Solar Panel AC supply Hence...

Page 9: ...rsal Over Temperature and Surge i Operating safely for at least one minute at 125 of rated power ii Operating safely for at least ten seconds at 150 of rated power iii Operating safely for at least fi...

Page 10: ...NOTE Because of EMIIT s policy of continuous product improvement the specifications are subject to change without notice 10...

Reviews: