Emist EPIX360 Manual Download Page 8

EN

Copyright ©2021 EMist, a MasVida Health Company. All rights reserved. All product names, logos, and brands are 

property of their respective owners. Prices are in U.S. Dollars. Prices are subject to change. All use of the website 

and resources is subject to the Terms of Use. EMI-018-21 Multilingual Manuals - 110321

8

ASSEMBLY & OPERATING INSTRUCTIONS

Tip: Charge battery first

 

1. Plug charger cord into wall outlet. 

 

2. Install battery into charger. 

 

3. Reference power indicator (3 bars = full charge)

Step 1: Install Battery into Charger.

 

y

To install, slide battery pack into the charger until the battery pack is 

firmly seated. It will click into the slot.- Note: Some chargers might 

require more force on first seat. 

 

y

Once battery is on the charger, a flashing red light indicates the battery 

is charging. 

 

y

Once the battery is fully charged, a solid red light will indicate the batter 

is fully charged.

- Tip: A fast blinking light on the charger indicates battery pack is not 

seated correctly. 

 

y

To remove battery from charger, grasp battery pack firmly, depress 

battery pack button down, and slide out from the charger. 

 

y

To check charge, press down on the battery indicator light, the light will 

illuminate 3 green bars when battery is fully charged.  

Step 2: Install Battery into Unit:

 

y

Slide the battery pack onto the base of the unit until firmly seated and 

snaps into place. 

 

Step 3: Liquid Tank Removal:

 

y

To remove the 8oz tank from the spray system hold the tank cap cover 

and the tank while gently pulling up the front of the tank from the spray 

system to remove it from the tank lock. Then pull up on the back to 

remove it from the tank back clip. 

 

y

This removes the whole tank assembly from the sprayer.

  

Step 4: Removing the Tank Cap Cover & Cap.

 

 

y

With the tank removed from the sprayer and holding it vertically, pull the 

tank cap cover straight up. No twisting is required.

 

y

To remove the tank cap, gently turn the cap counterclockwise until it is 

fully removed from the tank. 

Step 5: Installing the Tank Liner:

 

Tip: When you first receive your sprayer bundle, a tank liner is already 

installed in the tank for you. It includes the cap washer which is 

required for the liner to sit correctly into the tank itself. The liner is 

manufactured to last 100 spray hours or up to 3 months. 

 

y

When replacing your tank liner, first remove the used liner from the tank 

with the black cap washer by firmly holding the tank. 

 

y

Once removed from the tank, remove the liner from the black cap 

washer by holding the liner firmly in one hand, and pushing upwards on 

the washer to remove it from the liner threads. 

 

y

Get new liner, push the black cap washer on by pushing it down around 

the spout of the liner. Push the cap washer until the top of the liner spout 

and washer are flush with each other. 

Summary of Contents for EPIX360

Page 1: ...O P S M A N U A L Version 110321...

Page 2: ...eginning Included are assembly operating and safety instructions Following these manufacturer guidelines will help the system perform at peak effectiveness extend the life of the product and ensure op...

Page 3: ...els indicate a potentially hazardous situation which if not avoided could result in serious injury or death SAFETY NOTICES This manual contains information that is important for you to know and unders...

Page 4: ...ipment until you identify and correct the problem Use and clean equipment only in well ventilated area Never spray a flammable chemical with a flashpoint less than 60 C Do not turn lights on or off wh...

Page 5: ...protective equipment to help prevent serious injury PERSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment to help prevent serious injury WARNINGS Do not operate the unit when fatigued o...

Page 6: ...flash point less than 60 C Ensure the area being sprayed has proper ventilation Store all chemicals in original containers in a cool dry place away from heat and open flames Do not reuse or refill a c...

Page 7: ...sures proper fit and seal of tank cap assembly to the tank 3 Liquid Tank Liners The purpose of our disposable tank liners is to provide all directional spraying and the ability to use all the disinfec...

Page 8: ...ry pack onto the base of the unit until firmly seated and snaps into place Step 3 Liquid Tank Removal y To remove the 8oz tank from the spray system hold the tank cap cover and the tank while gently p...

Page 9: ...up the pump if this is done y Once this is completed pour the diluted or ready to use solution into the tank Step 6 Installing the Tank Cap and Cover y To install the tank cap gently turn clockwise ag...

Page 10: ...t for contact time as recommended by the chemical manufacturer s label before re entry into the area B SPRAY APPLICATION PROCESS 1 Make sure food and drinks are removed or covered before application 2...

Page 11: ...the applicator in an S pattern from bottom to the top of the surface target area in a continuous motion 2 Stay in motion electrostatically charged droplets will accumulate in higher levels at the tip...

Page 12: ...the recently flushed tank to begin next surface treatment Make sure the system is primed with the new solution by depressing the trigger button continuously for about 10 15 seconds FLUSHING THE ELECT...

Page 13: ...ot in use This keeps the unit from leaking or getting any fluid into the battery compartment or the contacts BATTERY REMOVAL Make sure the system is off Remove the battery from the sprayer by grasping...

Page 14: ...ry is mechanically obstructed System operates but red indicator light not illuminating High Voltage power supply LED is broken High voltage power supply is not working Call Customer Care No Mist or In...

Page 15: ...actured to function without defects The system will operate normally with properly maintained batteries and without abuse to any parts of the system If your system fails to return to normal use exclud...