background image

 
 
 
 

 

19 March, 2019

    

 

 

User Manual

 

GPS Vehicle Tracker 
EM201-Pro

 

 

 

D-325, SUMEL-8,  
Ajit Mill X Roads, Rakhial, 
Ahmedabad – 380023, GJ, INDIA

 

p.  +91 98256 14203      
     +91 87809 91242   
e.  [email protected] 

www.emiots.com

Summary of Contents for EM201-Pro

Page 1: ...19 March 2019 User Manual GPS Vehicle Tracker EM201 Pro D 325 SUMEL 8 Ajit Mill X Roads Rakhial Ahmedabad 380023 GJ INDIA p 91 98256 14203 91 87809 91242 e hello emiots com www emiots com...

Page 2: ...gram Cycle More than 20 Year data retention Internal backup battery Supports SIM card 1 8V and 3V Micro SIM Embedded SIM Optional Interface features Wide DC Input Voltage Range 9 to 32 Volt 2 Digital...

Page 3: ...mAh EM201 Pro operating time with internal backup battery depends on temperature data sending frequency SMS and GPRS and accumulator age and number of charge discharge cycle Charging temperature 0 45...

Page 4: ...ow DIN 2 SoS Green DIN 1 Ignition Black Ve Battery GND Red Ve Battery 9 32V DC Pin No Wire Color Pin Name Description 1 Red Ve Power Supply Pin 9 32 V DC 2 Black Ve Ground 3 Green DIN 1 Digital input...

Page 5: ...f GPS valid Blinking 200ms on 200ms off GPS fixed PROCESS LED Red Behavior Significance Off Ignition OFF Blinking 200ms on 200ms off Ignition ON GSM GPRS LED Green Behavior Significance Off Module Dev...

Page 6: ...S Fix Status 8 23 021171 Latitude 9 N Direction 10 72 632948 Longitude 11 E Direction 12 End Character 13 60 Checksum Tracking Packet Example Header 869867032596670 NR 1 15 5 23 021171 N 72 632948 E 4...

Page 7: ...cumulated distance 21 0 Distance from Last point 22 1000 Digital Input Status 1 Ignition Status 0 Reserved for future use 0 Panic Status 0 Reserved for future use 23 00 Digital Output Status 0 Digital...

Page 8: ...verip1 serverport1 serverip2 serverport2 serverip3 serv erport3 Example set_server 12345 123456 airtelgprs com 13 250 246 255 9022 13 250 246 255 9022 13 250 246 255 9022 2 SET_INTERVAL This command i...

Page 9: ...sage set_pwd serial password new password Example set_pwd 12345 123456 654321 Note This will change password and store 7 SET_FACTORY This command should restore every setting to factory mode and erase...

Page 10: ...User Manual www emiots com Page 9 of 13 Example set_serial 12345 123456 1234567...

Page 11: ...P address of the server PORT TCP Port Of Server GPS YES NO Fix Status GPRS Signal Level INTON on interval INTOFF off interval SR 180012345 APN airtelgprs com IP 13 250 222 225 PORT 9022 GPS YES GPRS 4...

Page 12: ...m maps q 15 623037 18 388672 5 chk_io This command will get current IO status Usage chk_io password Example chk_io 12345 Response IGN igniton status DIN1 digital 1 DIN2 digitl 2 AIN1 analog1 AIN2 anal...

Page 13: ...password on off 0 Example ctl_do1 180012345 12345 on 0 ctl_do1 180012345 12345 off 0 2 CTL_DO2 This command will activate digital IO2 Usage ctl_do2 serial password on off 1 Example ctl_do2 180012345...

Reviews: