4. Stick the conversion label on the rating plate as shown in Figure 10
Metal Rating Plate
5.
6.
7.
8.
9.
10.
11.
Figure 10 Conversion Label
LIGHTING INSTRUCTIONS
1. Locate the control and igniter panel. Make sure the
control knob is in the “OFF” position. See Figure 11. Open
the tank door and open the tank valve all the way.
2. Push in the igniter button. You will hear a slight clicking
sound. With the igniter button pushed in, push and turn the
control knob to the “ON” position. The fire should light within
a few seconds. Once the flame is lit, release the igniter
button and continue to hold the control knob in for 10 to 15
seconds. Release the control knob. The control knob
should pop back out and the fire should remain lit. Note: If
the fire does not light, turn the knob to the “OFF” position
and wait five (5) minutes before trying again.
3. To turn down the flame, push the control knob in slightly
and turn to the Medium (medium flame) or Low (small
flame).
4. To shut down the fire pit, turn the control knob to the
“OFF” position and turn off the tank valve
MAINTENANCE
The flames should look like those in Figure 12 To clean
the burner, use a soft brush after the burner and lava
rocks have cooled completely. Never use a vacuum
cleaner on the lava rocks. It is recommended that the lava
rocks be stored indoors during the winter if they will be
subjected to freezing temperatures. The propane cylinder
must be disconnected and removed from the appliance
before the appliance can be stored indoors.
Serial Number _________________
Model Number: 98900
CAUTION:
The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of
This appliance has been converted to use Natural Gas. Input 40,000 Btu/hr.
Max Gas Supply Pressure 7 inch w.c. (1.74 kPa) Min. Gas Supply Pressure 5 inch w.c. (1.24 kPa)
Minimum clearance from combustible constructions: Sides: 24 in.609 mm. Top 72 in. 1828 mm.
FOR OUTDOOR USE ONLY.
If stored indoors, detach and leave cylinder outdoors.